Cannulated screw unraveling: a case series and literature-based review of an under-recognized complication.

Eli Kupperman1, Orrin Franko, Andrew Indresano, Paul Girard.   

Abstract

Partially threaded cannulated screws have enhanced the orthopedic surgeon's ability to fix periarticular fractures. There are many reports of complications and hardware failure during screw removal, but those during fracture fixation are under-reported and under-recognized in the literature. We describe a 21-year-old healthy man with a grade 1 open displaced medial epicondylar humerus fracture. Upon fracture fixation in the OR using a partially threaded cannulated screw over a Kirschner wire, the threads of the screw unraveled. The operating surgeon felt increased resistance and the unraveling was demonstrated on intra-operative fluoroscopy. The screw was removed by hand without hardware retention and a new K-wire and cannulated screw were used for definitive fixation. We found seven previous cases reporting a similar complication with mixed presentations and results. All occurred in young healthy patients, six of which were males. Six of the seven cases made no mention of a tactile change in resistance during fixation and only one of the seven pre-drilled the cortex prior to placement of the cannulated screw. We believe that screw unraveling is an under-reported complication of fracture fixation with cannulated screws that should be recognized by the orthopedic community. We found intra-operative fluoroscopy integral to the recognition of the problem in our case and recommend its use in fracture fixation with cannulated screws. We also suggest pre-drilling of cortices, especially when operating on young patients with strong bone.

Entities:  

Mesh:

Year:  2012        PMID: 23104015     DOI: 10.1007/s00402-012-1638-9

Source DB:  PubMed          Journal:  Arch Orthop Trauma Surg        ISSN: 0936-8051            Impact factor:   3.067


  3 in total

1.  Arthroscopic Reinsertion of Lateral Collateral Ligament, Anterior Capsular Plication, and Coronoid Tunneling Technique for Chronic Elbow Posterolateral Rotatory Instability.

Authors:  Paolo Arrigoni; Riccardo D'Ambrosi; Simone Nicoletti; Pietro Randelli
Journal:  Arthrosc Tech       Date:  2016-05-09

2.  Thread Delamination in 4.5 mm AO Cannulated Screws: A Small Case Series in the Pediatric Trauma Population.

Authors:  Christopher D Murawski; Rajiv P Reddy; Robert T Tisherman; Patrick P Bosch; Jan S Grudziak; Stephen A Mendelson; W Timothy Ward; Zeynep Deniz Olgun
Journal:  J Pediatr Orthop       Date:  2022-03-01       Impact factor: 2.324

3.  Use of Cannulated Screws for Primary Latarjet Procedures.

Authors:  Simon Rattier; Thibaut Druel; Yoshihiro Hirakawa; Falk Gröger; Floris van Rooij; Lionel Neyton
Journal:  Orthop J Sports Med       Date:  2022-08-25
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.