Literature DB >> 23101531

Assessment of velocity, range, and smoothness of wrist circumduction using flexible electrogoniometry.

Harvinder P Singh1, Joseph J Dias, Harm Slijper, Steven Hovius.   

Abstract

PURPOSE: To quantify the range, velocity, and smoothness of wrist circumduction, to explore the oblique functional plane of wrist circumduction, and to establish the reproducibility and reliability of these measures.
METHODS: Forty healthy subjects with a mean age of 43 years and without a history of wrist pathology or pain participated in this study. We used a flexible electrogoniometer with a twin-axis sensor to measure the relative angles between the 2 end blocks while the subject performed maximum excursion of flexion-extension, radioulnar deviation, and circumduction of the wrist held in a standardized, fully pronated position. A software package was used to further analyze the characteristics of the circumduction curve or oval such as the mean area (designated as degree-degree or oo) shape, size, rate, smoothness, and orientation.
RESULTS: The mean area of circumduction (4729 [degree-degree]) and circumference (265°) of the circumduction curve indicated the total range of circumduction. The velocity of circumduction (mean 179°/s) and the time (1.6 second) taken to complete 1 cycle of circumduction were similar in both hands. The 4 quadrants for the velocity of circumduction showed that the velocity was faster in the radioulnar deviation quadrants compared with flexion and extension. Quadrant analysis showed the smoothness was greater in the radioulnar deviation quadrants than in the flexion and extension quadrants. The oblique planes of the circumduction curves of all the normal wrists lie in ulnopalmar and radiodorsal direction with a mean angle of 28° to the vertical flexion and extension plane.
CONCLUSIONS: This technique was accurate and reliable in measuring the velocity, range, and smoothness of wrist circumduction.
Copyright © 2012 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2012        PMID: 23101531     DOI: 10.1016/j.jhsa.2012.08.025

Source DB:  PubMed          Journal:  J Hand Surg Am        ISSN: 0363-5023            Impact factor:   2.230


  4 in total

1.  Results of the Universal 2 Prosthesis in Noninflammatory Osteoarthritic Wrists.

Authors:  M E Brinkhorst; R W Selles; J J Dias; H P Singh; R Feitz; T M Moojen; S E R Hovius
Journal:  J Wrist Surg       Date:  2017-08-24

2.  Design and Performance Analysis of a Dynamic Magnetic Resonance Imaging-Compatible Device for Triangular Fibrocartilage Complex Injury Diagnosis.

Authors:  Jiayu Fu; Hui Zhang; Kaiqi Wei; Chao Shi; Wei Zong
Journal:  J Healthc Eng       Date:  2022-06-16       Impact factor: 3.822

3.  Universal goniometer and electro-goniometer intra-examiner reliability in measuring the knee range of motion during active knee extension test in patients with chronic low back pain with short hamstring muscle.

Authors:  MohammadBagher Shamsi; Maryam Mirzaei; Seyyed Saeed Khabiri
Journal:  BMC Sports Sci Med Rehabil       Date:  2019-03-22

4.  Feasibility of a New Desktop Motion Analysis System with a Video Game Console for Assessing Various Three-Dimensional Wrist Motions.

Authors:  Kwang Gi Kim; Chan Soo Park; Suk Ha Jeon; Eui Yub Jung; Jiyun Ha; Sanglim Lee
Journal:  Clin Orthop Surg       Date:  2018-11-21
  4 in total