Literature DB >> 23097569

Estimation of glomerular filtration rate in rabbits by a single-sample method using iodixanol.

Y Michigoshi1, R Katayama, N Yamagishi, M Kato, J Saito, H Satoh, K Furuhama.   

Abstract

To estimate the glomerular filtration rate (GFR) in conscious rabbits, a single-sample method using the non-ionic contrast medium iodixanol was compared with a three-sample method using the standard agent inulin. Iodixanol and inulin were co-administered intravenously to male New Zealand White rabbits at 60 mg I/kg and 40 mg/kg, respectively, and blood was collected 30, 60, 90 and 120 min later. Serum iodixanol and inulin concentrations were separately determined by high performance liquid chromatography and colorimetry, respectively. Serum urea nitrogen (UN) and creatinine concentrations were also determined. Based on the data from healthy and cisplatin-treated rabbits, the GFR estimated by iodixanol was well consistent with that by inulin. Further, when the GFR decreased to more than 60% of the reference value, serum creatinine concentrations became elevated. However, serum UN concentrations exhibited wide fluctuations, presumably due to a difference in renal handlings. The single-sample method using iodixanol was considered to be an expedient tool in both clinical and research settings, because the stress due to a multi-sample method was reduced.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 23097569     DOI: 10.1258/la.2012.011065

Source DB:  PubMed          Journal:  Lab Anim        ISSN: 0023-6772            Impact factor:   2.471


  3 in total

1.  Influence of Molecular size on the clearance of antibody fragments.

Authors:  Zhe Li; Ben-Fillippo Krippendorff; Dhaval K Shah
Journal:  Pharm Res       Date:  2017-07-05       Impact factor: 4.200

2.  Development and validation of a physiology-based model for the prediction of pharmacokinetics/toxicokinetics in rabbits.

Authors:  Panteleimon D Mavroudis; Helen E Hermes; Donato Teutonico; Thomas G Preuss; Sebastian Schneckener
Journal:  PLoS One       Date:  2018-03-21       Impact factor: 3.240

Review 3.  In vivo X-ray computed tomographic imaging of soft tissue with native, intravenous, or oral contrast.

Authors:  Connor A Wathen; Nathan Foje; Tony van Avermaete; Bernadette Miramontes; Sarah E Chapaman; Todd A Sasser; Raghuraman Kannan; Steven Gerstler; W Matthew Leevy
Journal:  Sensors (Basel)       Date:  2013-05-27       Impact factor: 3.576

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.