Anup Katheria1, Wade Rich, Neil Finer. 1. Division of Neonatology, University of California San Diego Medical Center, University of California San Diego, San Diego, California, USA.
Abstract
OBJECTIVE: To compare the time required to obtain a continuous audible heart rate signal from an electrocardiogram (ECG) monitor and pulse oximeter (PO) in infants requiring resuscitation. METHODS: Infants who had both ECG and PO placed during resuscitation were analyzed using video and analog recordings. The median times from arrival until the ECG electrodes and PO sensor were placed, and the time to achieve audible tones from the devices, were compared. RESULTS: Forty-six infants had ECG and PO data. Thirty infants were very low birth weight (23-30 weeks). There was a difference in the median total time to place either device (26 vs 38 seconds; P = .04), and a difference (P < .001) in the time to achieve an audible heart rate signal after ECG lead (2 seconds) versus PO probe (24 seconds) placement. In infants weighing >1500 g (n = 16), the median time (interquartile range) to place the ECG was 20 seconds (14-43) whereas the time to place the PO was 36 seconds (28-56) (P = .74). The median times (interquartile range) to acquire a signal from the ECG and PO were 4 seconds (1-6) and 32 seconds (15-40, P = .001), respectively. During the first minutes of resuscitation, 93% of infants had an ECG heart rate compared with only 56% for PO. CONCLUSIONS: Early application of ECG electrodes during infant resuscitation can provide the resuscitation team with a continuous audible heart rate, and its use may improve the timeliness of appropriate critical interventions.
OBJECTIVE: To compare the time required to obtain a continuous audible heart rate signal from an electrocardiogram (ECG) monitor and pulse oximeter (PO) in infants requiring resuscitation. METHODS:Infants who had both ECG and PO placed during resuscitation were analyzed using video and analog recordings. The median times from arrival until the ECG electrodes and PO sensor were placed, and the time to achieve audible tones from the devices, were compared. RESULTS: Forty-six infants had ECG and PO data. Thirty infants were very low birth weight (23-30 weeks). There was a difference in the median total time to place either device (26 vs 38 seconds; P = .04), and a difference (P < .001) in the time to achieve an audible heart rate signal after ECG lead (2 seconds) versus PO probe (24 seconds) placement. In infants weighing >1500 g (n = 16), the median time (interquartile range) to place the ECG was 20 seconds (14-43) whereas the time to place the PO was 36 seconds (28-56) (P = .74). The median times (interquartile range) to acquire a signal from the ECG and PO were 4 seconds (1-6) and 32 seconds (15-40, P = .001), respectively. During the first minutes of resuscitation, 93% of infants had an ECG heart rate compared with only 56% for PO. CONCLUSIONS: Early application of ECG electrodes during infant resuscitation can provide the resuscitation team with a continuous audible heart rate, and its use may improve the timeliness of appropriate critical interventions.
Authors: Vishal Kapadia; Ju Lee Oei; Neil Finer; Wade Rich; Yacov Rabi; Ian M Wright; Denise Rook; Marijn J Vermeulen; William O Tarnow-Mordi; John P Smyth; Kei Lui; Steven Brown; Ola D Saugstad; Maximo Vento Journal: Resuscitation Date: 2021-08-20 Impact factor: 6.251
Authors: Caroline Henry; Lara Shipley; Stephen Morgan; John A Crowe; James Carpenter; Barrie Hayes-Gill; Don Sharkey Journal: Neonatology Date: 2022-02-07 Impact factor: 5.106
Authors: Denise C Jarrin; Jennifer J McGrath; Paul Poirier; Louise Séguin; Richard E Tremblay; Jacques Y Montplaisir; Gilles Paradis; Jean R Séguin Journal: Pediatr Cardiol Date: 2014-07-24 Impact factor: 1.655
Authors: John Madar; Charles C Roehr; Sean Ainsworth; Hege Ersda; Colin Morley; Mario Rüdiger; Christiane Skåre; Tomasz Szczapa; Arjan Te Pas; Daniele Trevisanuto; Berndt Urlesberger; Dominic Wilkinson; Jonathan P Wyllie Journal: Notf Rett Med Date: 2021-06-02 Impact factor: 0.892