Literature DB >> 23086888

High data output method for 3-D correlative light-electron microscopy using ultrathin cryosections.

Katia Cortese1, Giuseppe Vicidomini, Maria Cristina Gagliani, Patrizia Boccacci, Alberto Diaspro, Carlo Tacchetti.   

Abstract

Investigation of intracellular dynamics requires a detailed description of the molecular topography and ultrastructural morphology of the cell, for example, the position of a protein in relation to a given compartment of the cell and the morphology of the compartment. Standard fluorescence light microscopy (FLM) localizes proteins in living or fixed cells with a resolution of few hundreds of nanometers, but the unlabeled cellular context is partially missing. Electron microscopy (EM) techniques, such as immuno-EM, reveal protein topology with a few tens of nanometer resolution and retain the cellular context. However, EM analysis shows shortcomings compared to FLM, such as, lower statistical output, applicability only to fixed cells, and higher technical difficulties. To bridge the gap between fluorescent cell imaging and EM, several laboratories have developed methods for correlative light-electron microscopy (CLEM). In CLEM, a limited number of fluorescently labeled cell compartments are first imaged by light microscopy and then visualized and analyzed by EM. Recently, two different CLEM approaches using the EM cryo-immunogold method have been developed to extend the analysis to a high number of regions of interest and to correlate the topology of specific antigens. In this chapter, we describe one of these methods, the High Data Output CLEM (HDO-CLEM) approach. The major benefits of HDO-CLEM are the possibility to (1) correlate several hundreds of events at the same time, (2) perform three-dimensional (3D) correlation, (3) immunolabel both endogenous and recombinantly tagged proteins at the same time, and (4) combine the high data analysis capability of FLM with the high precision-accuracy of transmission electron microscopy in a CLEM hybrid morphometric analysis. We have identified and optimized critical steps in sample preparation, defined routines for sample analysis and retracing of regions of interest, developed software for semi/fully automatic 3D FLM reconstruction and defined preliminary conditions for a hybrid light/electron microscopy morphometry approach.

Mesh:

Year:  2013        PMID: 23086888     DOI: 10.1007/978-1-62703-137-0_23

Source DB:  PubMed          Journal:  Methods Mol Biol        ISSN: 1064-3745


  2 in total

1.  α-Synuclein fibrils subvert lysosome structure and function for the propagation of protein misfolding between cells through tunneling nanotubes.

Authors:  Aysegul Dilsizoglu Senol; Maura Samarani; Sylvie Syan; Carlos M Guardia; Takashi Nonaka; Nalan Liv; Patricia Latour-Lambert; Masato Hasegawa; Judith Klumperman; Juan S Bonifacino; Chiara Zurzolo
Journal:  PLoS Biol       Date:  2021-07-20       Impact factor: 8.029

2.  TEM, SEM, and STEM-based immuno-CLEM workflows offer complementary advantages.

Authors:  Viola Oorschot; Benjamin W Lindsey; Jan Kaslin; Georg Ramm
Journal:  Sci Rep       Date:  2021-01-13       Impact factor: 4.379