Literature DB >> 23086785

Patient radiation exposure during transcatheter aortic valve replacement procedures.

Benoit Daneault1, Stephen Balter, Susheel K Kodali, Mathew R Williams, Philippe Généreux, George R Reiss, Jean-Michel Paradis, Philip Green, Ajay J Kirtane, Craig Smith, Jeffrey W Moses, Martin B Leon.   

Abstract

AIMS: To describe patient radiation utilisation during transcatheter aortic valve replacement (TAVR) on a series of consecutive patients. METHODS AND
RESULTS: Data on radiation exposure were prospectively collected for consecutive patients undergoing TAVR and percutaneous coronary interventions at our centre. Radiation dose during the procedure was recorded using the US Food and Drug Administration (FDA) reference point (Ka,r) and the dose area product (PKA). In addition to quantifying overall radiation doses during TAVR, radiation exposure during transfemoral (TF) (n=79) and transapical (TA) (n=26) cases was compared. The median radiation dose during TAVR was 1,639 mGy (983-2,420), or 188 (106-321) Gy*cm2. Radiation dose was significantly lower among TA patients using either the reference point (TA: 946 [777-1,261] vs. TF: 1,932 [1,383-2,614] mGy; p<0.001) or the dose area product (TA: 89 [60-115] vs. TF: 236 [164-338] Gy*cm2; p<0.001). Fluoroscopy time was lower for TA patients (TA: 10 [8-11] vs. TF: 30 [24-34] minutes; p<0.001). Operators experience did not affect radiation exposure for TF cases.
CONCLUSIONS: Radiation exposure during TAVR appears similar to other percutaneous coronary interventions of moderate complexity. Radiation doses were significantly lower for TA procedures. A higher dose of radiation in TF patients may be related to additional imaging requirements to optimise percutaneous vascular access and closure.

Entities:  

Mesh:

Year:  2012        PMID: 23086785      PMCID: PMC3718041          DOI: 10.4244/EIJV8I6A106

Source DB:  PubMed          Journal:  EuroIntervention        ISSN: 1774-024X            Impact factor:   6.534


  23 in total

1.  Transcatheter aortic valve implantation: early results of the FRANCE (FRench Aortic National CoreValve and Edwards) registry.

Authors:  Hélène Eltchaninoff; Alain Prat; Martine Gilard; Alain Leguerrier; Didier Blanchard; Gérard Fournial; Bernard Iung; Patrick Donzeau-Gouge; Christophe Tribouilloy; Jean-Louis Debrux; Alain Pavie; Pascal Gueret
Journal:  Eur Heart J       Date:  2010-09-15       Impact factor: 29.983

2.  Transcatheter aortic-valve implantation for aortic stenosis in patients who cannot undergo surgery.

Authors:  Martin B Leon; Craig R Smith; Michael Mack; D Craig Miller; Jeffrey W Moses; Lars G Svensson; E Murat Tuzcu; John G Webb; Gregory P Fontana; Raj R Makkar; David L Brown; Peter C Block; Robert A Guyton; Augusto D Pichard; Joseph E Bavaria; Howard C Herrmann; Pamela S Douglas; John L Petersen; Jodi J Akin; William N Anderson; Duolao Wang; Stuart Pocock
Journal:  N Engl J Med       Date:  2010-09-22       Impact factor: 91.245

3.  Usefulness of TEE as the primary imaging technique to guide transcatheter transapical aortic valve implantation.

Authors:  Rodrigo Bagur; Josep Rodés-Cabau; Daniel Doyle; Robert De Larochellière; Jacques Villeneuve; Jerôme Lemieux; Sébastien Bergeron; Mélanie Côté; Olivier F Bertrand; Philippe Pibarot; Eric Dumont
Journal:  JACC Cardiovasc Imaging       Date:  2011-02

4.  Transcatheter aortic valve implantation: first results from a multi-centre real-world registry.

Authors:  Ralf Zahn; Ulrich Gerckens; Eberhard Grube; Axel Linke; Horst Sievert; Holger Eggebrecht; Rainer Hambrecht; Stefan Sack; Karl Eugen Hauptmann; Gert Richardt; Hans-Reiner Figulla; Jochen Senges
Journal:  Eur Heart J       Date:  2010-09-23       Impact factor: 29.983

5.  Thirty-day results of the SAPIEN aortic Bioprosthesis European Outcome (SOURCE) Registry: A European registry of transcatheter aortic valve implantation using the Edwards SAPIEN valve.

Authors:  Martyn Thomas; Gerhard Schymik; Thomas Walther; Dominique Himbert; Thierry Lefèvre; Hendrik Treede; Holger Eggebrecht; Paolo Rubino; Iassen Michev; Rüdiger Lange; William N Anderson; Olaf Wendler
Journal:  Circulation       Date:  2010-06-21       Impact factor: 29.690

Review 6.  Radiation safety program for the cardiac catheterization laboratory.

Authors:  Charles E Chambers; Kenneth A Fetterly; Ralf Holzer; Pei-Jan Paul Lin; James C Blankenship; Stephen Balter; Warren K Laskey
Journal:  Catheter Cardiovasc Interv       Date:  2011-01-19       Impact factor: 2.692

7.  Dosimetric data and radiation risk analysis for new procedures in interventional cardiology.

Authors:  P Signorotto; A del Vecchio; M Montorfano; F Maisano; M Giagnorio; R Bellanca; A Colombo; R Calandrino
Journal:  Radiat Prot Dosimetry       Date:  2010-09-21       Impact factor: 0.972

8.  Safety and efficacy of the subclavian approach for transcatheter aortic valve implantation with the CoreValve revalving system.

Authors:  Anna Sonia Petronio; Marco De Carlo; Francesco Bedogni; Antonio Marzocchi; Silvio Klugmann; Francesco Maisano; Angelo Ramondo; Gian Paolo Ussia; Federica Ettori; Arnaldo Poli; Nedy Brambilla; Francesco Saia; Federico De Marco; Antonio Colombo
Journal:  Circ Cardiovasc Interv       Date:  2010-07-06       Impact factor: 6.546

Review 9.  Clinical radiation management for fluoroscopically guided interventional procedures.

Authors:  Donald L Miller; Stephen Balter; Beth A Schueler; Louis K Wagner; Keith J Strauss; Eliseo Vañó
Journal:  Radiology       Date:  2010-11       Impact factor: 11.105

10.  One year follow-up of the multi-centre European PARTNER transcatheter heart valve study.

Authors:  Thierry Lefèvre; Ari Pieter Kappetein; Ernst Wolner; Patrick Nataf; Martyn Thomas; Volker Schächinger; Bernard De Bruyne; Hélène Eltchaninoff; Matthias Thielmann; Dominique Himbert; Mauro Romano; Patrick Serruys; Gerhard Wimmer-Greinecker
Journal:  Eur Heart J       Date:  2010-11-12       Impact factor: 29.983

View more
  2 in total

1.  Radiation Exposure During Transcatheter Valve Replacement: What Cardiac Surgeons Need to Know.

Authors:  Alejandro Aquino; Ali J Khiabani; Matthew C Henn; Alan Zajarias; Spencer J Melby; Marc Sintek; John Lasala; Puja Kachroo; Eric Novak; Hersh S Maniar
Journal:  Ann Thorac Surg       Date:  2019-07-06       Impact factor: 4.330

2.  C-arm rotation as a method for reducing peak skin dose in interventional cardiology.

Authors:  Alexander S Pasciak; Austin C Bourgeois; A Kyle Jones
Journal:  Open Heart       Date:  2014-12-23
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.