PURPOSE: To determine the refractive outcomes of wavefront-optimized laser in situ keratomileusis (LASIK) treatments, in particular to measure corneal densitometry after LASIK using the densitometry function of the Pentacam Scheimpflug system. SETTING: Division of Ophthalmology and Visual Sciences, University of Nottingham, United Kingdom. DESIGN: Cohort study. METHODS: Changes in postoperative visual acuity, refraction, and contrast sensitivity were evaluated after wavefront-optimized laser treatment. Corneal densitometry was evaluated with the Scheimpflug system before and after LASIK. RESULTS: One year postoperatively, the uncorrected distance visual acuity was 6/6 or better in 92% of eyes and 6/9 or better in all eyes. Eighty-six percent of eyes had no change in the corrected distance visual acuity (CDVA); 4% gained 1 or more lines. Wavefront-optimized LASIK was stable over 1 year postoperatively. Eighty-nine percent of eyes were within ±0.50 diopter (D) and 100% were within ±1.00 D of the intended correction 1 year postoperatively. Contrast sensitivity showed a nonsignificant improvement (1.55 ± 0.10 [SD] preoperatively to 1.57 ± 0.09 12 months postoperatively) (P > .05). There was a nonsignificant increase in corneal densitometry 1 year postoperatively (from 12.72 ± 2.43 to 13.04 ± 2.58) (P > .05). No correlation was found between corneal densitometry and contrast sensitivity or CDVA. CONCLUSIONS: Wavefront-optimized LASIK gave excellent refractive and visual outcomes and did not seem to affect corneal densitometry significantly 1 year postoperatively. However, larger studies may show a masked effect on corneal densitometry. FINANCIAL DISCLOSURE: No author has a financial or proprietary interest in any material or method mentioned.
PURPOSE: To determine the refractive outcomes of wavefront-optimized laser in situ keratomileusis (LASIK) treatments, in particular to measure corneal densitometry after LASIK using the densitometry function of the Pentacam Scheimpflug system. SETTING: Division of Ophthalmology and Visual Sciences, University of Nottingham, United Kingdom. DESIGN: Cohort study. METHODS: Changes in postoperative visual acuity, refraction, and contrast sensitivity were evaluated after wavefront-optimized laser treatment. Corneal densitometry was evaluated with the Scheimpflug system before and after LASIK. RESULTS: One year postoperatively, the uncorrected distance visual acuity was 6/6 or better in 92% of eyes and 6/9 or better in all eyes. Eighty-six percent of eyes had no change in the corrected distance visual acuity (CDVA); 4% gained 1 or more lines. Wavefront-optimized LASIK was stable over 1 year postoperatively. Eighty-nine percent of eyes were within ±0.50 diopter (D) and 100% were within ±1.00 D of the intended correction 1 year postoperatively. Contrast sensitivity showed a nonsignificant improvement (1.55 ± 0.10 [SD] preoperatively to 1.57 ± 0.09 12 months postoperatively) (P > .05). There was a nonsignificant increase in corneal densitometry 1 year postoperatively (from 12.72 ± 2.43 to 13.04 ± 2.58) (P > .05). No correlation was found between corneal densitometry and contrast sensitivity or CDVA. CONCLUSIONS: Wavefront-optimized LASIK gave excellent refractive and visual outcomes and did not seem to affect corneal densitometry significantly 1 year postoperatively. However, larger studies may show a masked effect on corneal densitometry. FINANCIAL DISCLOSURE: No author has a financial or proprietary interest in any material or method mentioned.
Authors: F Poyales; N Garzón; J Mendicute; I Illarramendi; P Caro; O Jáñez; F Argüeso; A López Journal: Eye (Lond) Date: 2017-06-16 Impact factor: 3.775
Authors: Kristin E Hirabayashi; Winston Chamberlain; Jennifer Rose-Nussbaumer; Ariana Austin; Laurel Stell; Charles C Lin Journal: Cornea Date: 2020-06 Impact factor: 2.651
Authors: Nuria Garzón; Francisco Poyales; Igor Illarramendi; Javier Mendicute; Óscar Jáñez; Pedro Caro; Alfredo López; Francisco Argüeso Journal: Int Ophthalmol Date: 2016-11-11 Impact factor: 2.031
Authors: Chris H L Lim; Andri K Riau; Nyein C Lwin; Shyam S Chaurasia; Donald T Tan; Jodhbir S Mehta Journal: PLoS One Date: 2013-12-11 Impact factor: 3.240