BACKGROUND: Catheter hub decontamination requires a thorough scrub and compliance varies. This study evaluates the effectiveness of a disinfection cap with 70% alcohol in preventing contamination/infection. METHODS: A 3-phased, multifacility, quasi-experimental study of adult patients with central lines divided into P1 (baseline), when the standard scrub was used; P2, when the cap was used on all central lines; and P3, when standard disinfection was reinstituted. House-wide central-line associated bloodstream infection (CLABSI) rates are reported with catheter-associated urinary tract infections (CAUTI) as a control measure. Adults with peripherally inserted central catheters inserted during hospitalization having 5+ consecutive line-days gave consent and were enrolled, and 1.5 mL of blood was withdrawn from each lumen not in use and quantitatively cultured. RESULTS: Contamination was 12.7% (32/252) during P1; 5.5% (20/364) in P2 (P = .002), and 12.0% (22/183; P = 0.88 vs P1 and P = .01 vs P2) in P3 (P = .001 vs P2). The median colony-forming units per milliliter was 4 for P1, 1 for P2 (P = .009), and 2 for P3 (P = .05 vs P2). CLABSI rates declined from 1.43 per 1,000 line-days (16/11,154) to 0.69 (13/18,972) in P2 (P = .04) and increased to 1.31 (7/5,354) in P3. CAUTI rates remained stable between P1 and P2 (1.42 and 1.41, respectively, P = .90) but declined in P3 (1.04, P = .03 vs P1 and P2). CONCLUSION: Disinfecting caps reduce line contamination, organism density, and CLABSIs.
BACKGROUND: Catheter hub decontamination requires a thorough scrub and compliance varies. This study evaluates the effectiveness of a disinfection cap with 70% alcohol in preventing contamination/infection. METHODS: A 3-phased, multifacility, quasi-experimental study of adult patients with central lines divided into P1 (baseline), when the standard scrub was used; P2, when the cap was used on all central lines; and P3, when standard disinfection was reinstituted. House-wide central-line associated bloodstream infection (CLABSI) rates are reported with catheter-associated urinary tract infections (CAUTI) as a control measure. Adults with peripherally inserted central catheters inserted during hospitalization having 5+ consecutive line-days gave consent and were enrolled, and 1.5 mL of blood was withdrawn from each lumen not in use and quantitatively cultured. RESULTS: Contamination was 12.7% (32/252) during P1; 5.5% (20/364) in P2 (P = .002), and 12.0% (22/183; P = 0.88 vs P1 and P = .01 vs P2) in P3 (P = .001 vs P2). The median colony-forming units per milliliter was 4 for P1, 1 for P2 (P = .009), and 2 for P3 (P = .05 vs P2). CLABSI rates declined from 1.43 per 1,000 line-days (16/11,154) to 0.69 (13/18,972) in P2 (P = .04) and increased to 1.31 (7/5,354) in P3. CAUTI rates remained stable between P1 and P2 (1.42 and 1.41, respectively, P = .90) but declined in P3 (1.04, P = .03 vs P1 and P2). CONCLUSION: Disinfecting caps reduce line contamination, organism density, and CLABSIs.
Authors: Fernando Gutiérrez Nicolás; Gloria Julia Nazco Casariego; María Micaela Viña Romero; Jonathan González García; Ruth Ramos Diaz; Jose Antonio Perez Perez Journal: Eur J Hosp Pharm Date: 2015-10-12
Authors: Aaron M Milstone; Carol Rosenberg; Gayane Yenokyan; Danielle W Koontz; Marlene R Miller Journal: Infect Control Hosp Epidemiol Date: 2020-10-12 Impact factor: 3.254
Authors: Niccolò Buetti; Jonas Marschall; Marci Drees; Mohamad G Fakih; Lynn Hadaway; Lisa L Maragakis; Elizabeth Monsees; Shannon Novosad; Naomi P O'Grady; Mark E Rupp; Joshua Wolf; Deborah Yokoe; Leonard A Mermel Journal: Infect Control Hosp Epidemiol Date: 2022-04-19 Impact factor: 6.520
Authors: Anna L Casey; Tarja J Karpanen; Peter Nightingale; Tom S J Elliott Journal: Antimicrob Resist Infect Control Date: 2018-04-05 Impact factor: 4.887