PURPOSE: Two-dimensional projection reconstruction methods provide advantages over three-dimensional techniques because of higher flexibility regarding the resolution and shorter scan time needed. To optimize a two-dimensional radial sequence with respect to signal-to-noise ratio, variable-rate selective excitation and retrospective electrocardiogram gating is investigated. METHODS: The minimal radiofrequency pulse duration is simulated in dependence of the flip angle and coil parameters using sinc waveforms with two different variable-rate selective excitation approaches and a Fermi pulse. Retrospectively electrocardiogram-gated imaging with Golden Angle incremented projections was implemented to allow for continuous data acquisition enabling the possibility of dynamic electrocardiogram-gated heart imaging. RESULTS: Especially for abdominal coils with high transmitter voltages required, variable-rate selective excitation strongly reduces the radiofrequency pulse duration and echo time resulting in a signal-to-noise ratio gain up to 15.5% (if the fast relaxation component of sodium is in the order of the radiofrequency pulse duration) compared with standard sinc-shaped radiofrequency pulses. Retrospective electrocardiogram gating shows higher flexibility with regard to the trigger delay enabling the trade-off between heart motion artifacts and signal-to-noise ratio. CONCLUSION: A two-dimensional radial sequence is optimized for sodium heart imaging regarding signal-to-noise ratio. Different sodium contrasts of the human heart are shown, which can give additional information on heart diseases.
PURPOSE: Two-dimensional projection reconstruction methods provide advantages over three-dimensional techniques because of higher flexibility regarding the resolution and shorter scan time needed. To optimize a two-dimensional radial sequence with respect to signal-to-noise ratio, variable-rate selective excitation and retrospective electrocardiogram gating is investigated. METHODS: The minimal radiofrequency pulse duration is simulated in dependence of the flip angle and coil parameters using sinc waveforms with two different variable-rate selective excitation approaches and a Fermi pulse. Retrospectively electrocardiogram-gated imaging with Golden Angle incremented projections was implemented to allow for continuous data acquisition enabling the possibility of dynamic electrocardiogram-gated heart imaging. RESULTS: Especially for abdominal coils with high transmitter voltages required, variable-rate selective excitation strongly reduces the radiofrequency pulse duration and echo time resulting in a signal-to-noise ratio gain up to 15.5% (if the fast relaxation component of sodium is in the order of the radiofrequency pulse duration) compared with standard sinc-shaped radiofrequency pulses. Retrospective electrocardiogram gating shows higher flexibility with regard to the trigger delay enabling the trade-off between heart motion artifacts and signal-to-noise ratio. CONCLUSION: A two-dimensional radial sequence is optimized for sodium heart imaging regarding signal-to-noise ratio. Different sodium contrasts of the human heart are shown, which can give additional information on heart diseases.
Authors: Melissa M Meyer; Stefan Haneder; Simon Konstandin; Johannes Budjan; John N Morelli; Lothar R Schad; Hans U Kerl; Stefan O Schoenberg; Christoph Kabbasch Journal: BMC Med Imaging Date: 2019-04-03 Impact factor: 1.930