Literature DB >> 23080350

A 3-dimensional ultrasound study of local anesthetic spread during lateral popliteal nerve block: what is the ideal end point for needle tip position?

Andres Missair1, Robyn S Weisman, Maria Rene Suarez, Relin Yang, Ralf E Gebhard.   

Abstract

BACKGROUND AND OBJECTIVES: Recent clinical trials suggest that subfascial (sometimes termed subepineural) injections result in faster block onset and success compared with conventional techniques. This prospective, randomized, observer-blinded study measured and compared the 3-dimensional spread pattern and volume of perineural local anesthetic (LA) in contact with the sciatic nerve after subfascial versus extrafascial lateral popliteal injections.
METHODS: Sixty patients were randomly assigned to either the subfascial or the extrafascial injection group. All patients received a single-injection, US-guided lateral popliteal sciatic nerve block for postoperative pain. Depending on group assignment, the needle tip was placed outside or beneath the sciatic fascial sheath for a single injection of 30 mL of ropivacaine 0.5%. Using 3-dimensional ultrasound imaging, postblock scans were acquired to quantify the volume and spread pattern of perineural LA around the sciatic nerve in each group.
RESULTS: The mean LA perineural volume for the extrafascial group was 1.48 (SD, 0.50) mL versus a mean of 5.57 (SD, 1.68) mL for the subfascial group, P < 0.05. The mean distance of longitudinal perineural LA spread (along the length of the nerve) for the subfascial group was 66% greater than that observed using the conventional technique (9.3 vs 5.6 cm, P < 0.01). Complete sensory block to pinprick for the extrafascial group was 63% versus 90% (P < 0.05) for the subfascial group.
CONCLUSIONS: Placement of the needle tip beneath the complex fascial sheath of the sciatic nerve resulted in significantly greater perineural local anesthetic volume following a single-injection lateral popliteal approach at the nerve bifurcation and was associated with greater sensory blockade and a characteristic laminar LA spread pattern.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 23080350     DOI: 10.1097/AAP.0b013e31826af511

Source DB:  PubMed          Journal:  Reg Anesth Pain Med        ISSN: 1098-7339            Impact factor:   6.288


  9 in total

1.  Temporal profile of the effects of regional anesthesia on the cutaneous reflexes of foot muscles.

Authors:  Isabella A Mota; João B Fernandes; Marcio N Cardoso; Xavier Sala-Blanch; Markus Kofler; Josep Valls-Solé
Journal:  Exp Brain Res       Date:  2015-05-30       Impact factor: 1.972

Review 2.  [Seeing more : Technical innovations in regional anesthesia].

Authors:  T Wiesmann; T Steinfeldt; T Volk; U Schwemmer; P Kessler; H Wulf
Journal:  Anaesthesist       Date:  2014-11       Impact factor: 1.041

3.  Ultrasound-guided sciatic nerve block: a comparison between four different infragluteal probe and needle alignment approaches.

Authors:  Tarek F Tammam
Journal:  J Anesth       Date:  2013-12-06       Impact factor: 2.078

4.  [Distal sciatic nerve blocks: randomized comparison of nerve stimulation and ultrasound guided intraepineural block].

Authors:  R Seidel; U Natge; J Schulz
Journal:  Anaesthesist       Date:  2013-03-16       Impact factor: 1.041

Review 5.  An update around the evidence base for the lower extremity ultrasound regional block technique.

Authors:  Andrea Fanelli; Daniela Ghisi; Rita Maria Melotti
Journal:  F1000Res       Date:  2016-01-26

6.  Minimum effective local anesthetic volume for surgical anesthesia by subparaneural, ultrasound-guided popliteal sciatic nerve block: A prospective dose-finding study.

Authors:  Seung Uk Bang; Dong Ju Kim; Jin Ho Bae; Kyudon Chung; Yeesuk Kim
Journal:  Medicine (Baltimore)       Date:  2016-08       Impact factor: 1.889

7.  Mean effective volume of local anesthetics by nerve conduction technique.

Authors:  Junjie Luo; Guangyu Cai; Dandan Ling; Na Zhang; Xiaorui Chen; Xiaodan Cao; Bin Yu
Journal:  Ann Transl Med       Date:  2020-03

8.  Extraplexus versus intraplexus ultrasound-guided interscalene brachial plexus block for ambulatory arthroscopic shoulder surgery: A randomized controlled trial.

Authors:  Monica W Harbell; Kerstin Kolodzie; Matthias Behrends; C Benjamin Ma; Sakura Kinjo; Edward Yap; Matthias R Braehler; Pedram Aleshi
Journal:  PLoS One       Date:  2021-02-18       Impact factor: 3.240

9.  A standardized method for 4D ultrasound-guided peripheral nerve blockade and catheter placement.

Authors:  N J Clendenen; C B Robards; S R Clendenen
Journal:  Biomed Res Int       Date:  2014-01-19       Impact factor: 3.411

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.