Literature DB >> 23078284

Assessment of adequate removal of ophthalmic viscoelastic device with irrigation/aspiration by quantifying intraocular lens 'Judders'.

Benjamin W C Sim1, Shahriar Amjadi, Ravjit Singh, Gaurav Bhardwaj, Rahul Dubey, Ian C Francis.   

Abstract

BACKGROUND: To assess the efficacy of 'Judders' as a technique reflecting adequacy of removal of ophthalmic viscoelastic device in cataract surgery.
DESIGN: Prospective, consecutive, single surgeon study. PARTICIPANTS: Cohort of 223 patients undergoing phacoemulsification.
METHODS: 'Judders' are periodic, abrupt, horizontal displacements of the intraocular lens causing balanced salt solution to displace retropseudophakic ophthalmic viscoelastic device. The number of 'Judders' was correlated with axial length, anterior chamber depth, and preoperative and postoperative intraocular pressure. MAIN OUTCOME MEASURES: Number of 'Judders', axial length, anterior chamber depth, day 1 postoperative intraocular pressure.
RESULTS: The mean number of 'Judders' was 3.2. There was a positive association between the number of 'Judders' and axial length, but not between number of 'Judders' and anterior chamber depth. Mean preoperative intraocular pressure was 14.5 mmHg; mean day 1 postoperative intraocular pressure was 15.6 mmHg. Intraocular pressure rose in 47% of cases. In six cases (5%), intraocular pressure rose greater than 10 mmHg (range 11-23 mmHg) from the preoperative level.
CONCLUSIONS: Aspirating ophthalmic viscoelastic device with the irrigation/aspiration tip posterior to the intraocular lens may be associated with the risk of a posterior capsule tear. Maintaining the irrigation/aspiration tip anterior to the intraocular lens may offer a significant safety advantage. The number of 'Judders', usually 3-4, appears to be a safe and reliable end-point of complete ophthalmic viscoelastic device removal. There were significantly more 'Judders' in eyes with a longer axial length. The safety and efficacy of 'Judders' are reflected by the stable mean postoperative intraocular pressure.
© 2012 The Authors. Clinical and Experimental Ophthalmology © 2012 Royal Australian and New Zealand College of Ophthalmologists.

Entities:  

Mesh:

Substances:

Year:  2013        PMID: 23078284     DOI: 10.1111/ceo.12024

Source DB:  PubMed          Journal:  Clin Exp Ophthalmol        ISSN: 1442-6404            Impact factor:   4.207


  3 in total

1.  Effects of phacoemulsification with versus without viscoelastic devices on surgical outcomes.

Authors:  İbrahim Taşkın; Lokman Aslan
Journal:  Int Ophthalmol       Date:  2017-05-09       Impact factor: 2.031

2.  Safety of hydroimplantation in cataract surgery in patients with pseudoexfoliation syndrome.

Authors:  Tevfik Oğurel; Reyhan Oğurel; Zafer Onaran; Kemal Örnek
Journal:  Int J Ophthalmol       Date:  2017-05-18       Impact factor: 1.779

3.  Evaluation of a new method of irrigation and aspiration for removal of ophthalmic viscoelastic device during cataract surgery in a porcine model.

Authors:  Arisa Mitani; Takashi Suzuki; Yoshitaka Tasaka; Takahiro Uda; Yukako Hiramatsu; Shiro Kawasaki; Yuichi Ohashi
Journal:  BMC Ophthalmol       Date:  2014-11-07       Impact factor: 2.209

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.