The purpose of this investigation was to test the performance of pertussis serology in diagnostic laboratories. The World Health Organization (WHO) Reference Reagent (06/142) and a sample with a low level of antibodies were sent to 200 participants of an external quality assessment (EQA) programme in Germany. The results were reported qualitatively and quantitatively, and were converted into IU/ml when possible. A total of 183 participants reported results. IgG, IgA and IgM enzyme-linked immunosorbent assays (ELISAs) with mixed antigens were used by 111, 110 and 113 participants, respectively, and 69 and 44 participants used IgG and IgA ELISAs with purified pertussis toxin (PT), respectively. IgG, IgA and IgM immunoblots were employed by 62, 63 and 11 participants, respectively. Most tests could distinguish between the positive and negative samples, but quantitative results were reported partly in non-comparable units. Only 37 % of participants used ELISAs that gave results comparable to the expected values in IU/ml and that could be interpreted according to published recommendations.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 23076769     DOI: 10.1007/s10096-012-1759-7

Source DB:  PubMed          Journal:  Eur J Clin Microbiol Infect Dis        ISSN: 0934-9723            Impact factor:   3.267


  6 in total

1.  Comparison of five commercial enzyme-linked immunosorbent assays for detection of antibodies to Bordetella pertussis.

Authors:  K Kösters; M Riffelmann; B Dohrn; C H von König
Journal:  Clin Diagn Lab Immunol       Date:  2000-05

2.  Is serological testing a reliable tool in laboratory diagnosis of syphilis? Meta-analysis of eight external quality control surveys performed by the german infection serology proficiency testing program.

Authors:  Iris Müller; Volker Brade; Hans-Jochen Hagedorn; Erich Straube; Christoph Schörner; Matthias Frosch; Harald Hlobil; Gerold Stanek; Klaus-Peter Hunfeld
Journal:  J Clin Microbiol       Date:  2006-04       Impact factor: 5.948

3.  Performance of commercial enzyme-linked immunosorbent assays for detection of antibodies to Bordetella pertussis.

Authors:  M Riffelmann; K Thiel; J Schmetz; C H Wirsing von Koenig
Journal:  J Clin Microbiol       Date:  2010-10-13       Impact factor: 5.948

4.  Characterization of reference materials for human antiserum to pertussis antigens by an international collaborative study.

Authors:  Dorothy Xing; Carl Heinz Wirsing von König; Penny Newland; Marion Riffelmann; Bruce D Meade; Michael Corbel; Rose Gaines-Das
Journal:  Clin Vaccine Immunol       Date:  2008-12-24

Review 5.  What to do and what not to do in serological diagnosis of pertussis: recommendations from EU reference laboratories.

Authors:  N Guiso; G Berbers; N K Fry; Q He; M Riffelmann; C H Wirsing von König
Journal:  Eur J Clin Microbiol Infect Dis       Date:  2010-11-11       Impact factor: 3.267

6.  Evaluating frequency, diagnostic quality, and cost of Lyme borreliosis testing in Germany: a retrospective model analysis.

Authors:  I Müller; M H Freitag; G Poggensee; E Scharnetzky; E Straube; Ch Schoerner; H Hlobil; H-J Hagedorn; G Stanek; A Schubert-Unkmeir; D E Norris; J Gensichen; K-P Hunfeld
Journal:  Clin Dev Immunol       Date:  2011-12-27