A prospective study of transit-time flow volume measurement for intraoperative evaluation and optimization of free flaps.

Jesse C Selber1, Patrick B Garvey, Mark W Clemens, Edward I Chang, Hong Zhang, Matthew M Hanasono.   

Abstract

BACKGROUND: Transit-time flow volume measurement, a non-Doppler-based ultrasound technology, has been shown to accurately evaluate the quality of coronary artery bypass grafts and improve outcomes of cardiac surgery. The authors hypothesized that it would also improve decision making in microvascular free tissue transfer procedures.
METHODS: The authors measured transit-time flow volume in 52 consecutive free flaps at three times: measurement 1 (in situ), after flap elevation and isolation on its pedicle; measurement 2 (time 1), immediately after anastomosis and reperfusion; and measurement 3 (time 2), 30 minutes after anastomosis and reperfusion. Intraoperative decisions based on transit-time flow volume were documented.
RESULTS: Arterial inflow was on average 1.5 times greater than venous outflow, and arterial resistance was 3.59 times greater than venous resistance. Free transverse rectus abdominis musculocutaneous flaps had the highest venous and arterial flows, and free radial forearm flaps had the lowest. Compared with the baseline (in situ) measurement, all flaps had higher flows immediately after transfer (time 1) (p < 0.0001), but no significant differences were seen 30 minutes later (time 2) (p = 0.68). Arterial resistance, however, increased during that interval (p = 0.006). Operative decisions, including selection of the higher flow vena comitans (sometimes the smaller of the two) and when to revise an anastomosis, were modified on the basis of volume findings in 19 of 52 cases (36.5 percent).
CONCLUSIONS: Transit-time flow volume provides novel physiologic flap data and identifies flawed anastomoses and higher flow venae comitantes. These data have clinical value in microsurgery and might reduce microvascular complications and improve outcomes. CLINICAL QUESTION/LEVEL OF EVIDENCDE: Diagnostic, IV.

Mesh:

Year:  2013        PMID: 23076414     DOI: 10.1097/PRS.0b013e3182789c91

Source DB:  PubMed          Journal:  Plast Reconstr Surg        ISSN: 0032-1052            Impact factor:   4.730


  3 in total

1.  Ischemia-reperfusion injury in a rat microvascular skin free flap model: A histological, genetic, and blood flow study.

Authors:  Alberto Ballestín; Javier G Casado; Elena Abellán; F Javier Vela; Verónica Álvarez; Alejandra Usón; Esther López; Federica Marinaro; Rebeca Blázquez; Francisco Miguel Sánchez-Margallo
Journal:  PLoS One       Date:  2018-12-27       Impact factor: 3.240

2.  Comparison of Fasciocutaneous and Muscle-based Free Flaps for Soft Tissue Reconstruction of the Upper Extremity.

Authors:  Christoph Koepple; Ann-Katrin Kallenberger; Lukas Pollmann; Gabriel Hundeshagen; Volker J Schmidt; Ulrich Kneser; Christoph Hirche
Journal:  Plast Reconstr Surg Glob Open       Date:  2019-12-31

3.  Intraoperative Blood Flow Analysis of DIEP vs. ms-TRAM Flap Breast Reconstruction Combining Transit-Time Flowmetry and Microvascular Indocyanine Green Angiography.

Authors:  Alexander Geierlehner; Raymund E Horch; Ingo Ludolph; Andreas Arkudas
Journal:  J Pers Med       Date:  2022-03-16
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.