Literature DB >> 23075859

Polyetheretherketone (PEEK) Rods in Lumbar Spine Degenerative Disease: A Case Series.

D Ryan Ormond1, Ladislau Albert, Kaushik Das.   

Abstract

STUDY
DESIGN: Retrospective case series.
OBJECTIVE: The purpose of our study was to retrospectively review the results of posterior lumbar fusion using polyetheretherketone (PEEK) rods. SUMMARY OF BACKGROUND DATA: Pedicle screw and rod instrumentation has become the preferred technique for performing stabilization and fusion in the lumbar spine for degenerative disease. Rigid fixation with titanium rods leads to high fusion rates, but may also contribute to stress shielding and adjacent segment degeneration (ASD). Thus, some have advocated using semirigid rods made of PEEK. Although the biomechanical properties of PEEK rods have shown improved stress-shielding characteristics and anterior load-sharing properties, there are very few clinical studies evaluating their application in the lumbar spine.
METHODS: We evaluated a retrospective cohort of 42 patients who underwent posterior lumbar fusion from 2007 to 2009 for the treatment of lumbar spine degenerative disease using PEEK rods. Reoperation rate was the primary outcome evaluated. Fusion rate was also evaluated.
RESULTS: Eight of the 42 patients with PEEK rods required reoperation. Reasons for reoperation mainly included ASD (5/8) and nonunion with cage migration (3/8). Radiographically, documented fusion rate was 86%. Mean follow-up was 31.4 months. No statistical differences were found in fusion rates or reoperation between age above 55 years and younger than 55 years (P=1.00), male and female (P=0.110), single or multilevel fusion (P=0.67), and fusion with and without an interbody graft (P=0.69). Smokers showed a trend towards increased risk of reoperation for ASD or instrumentation failure (P=0.056).
CONCLUSIONS: PEEK rods demonstrate a similar fusion and reoperation rate in comparison to other instrumentation modalities in the treatment of degenerative lumbar spine disease.

Entities:  

Mesh:

Substances:

Year:  2016        PMID: 23075859     DOI: 10.1097/BSD.0b013e318277cb9b

Source DB:  PubMed          Journal:  Clin Spine Surg        ISSN: 2380-0186            Impact factor:   1.876


  11 in total

1.  Comparison of clinical and radiological results of dynamic and rigid instrumentation in degenerative lumbar spinal stenosis.

Authors:  Eyup Varol; Mustafa Umut Etli; Furkan Avci; Cumhur Kaan Yaltirik; Ali Fatih Ramazanoglu; Mehmet Resid Onen; Sait Naderi
Journal:  J Craniovertebr Junction Spine       Date:  2022-09-14

2.  Polyetheretherketone (PEEK) Rods for Lumbar Fusion: A Systematic Review and Meta-Analysis.

Authors:  Abdulhafez Selim; Sarah Mercer; Feng Tang
Journal:  Int J Spine Surg       Date:  2018-08-03

3.  Biomechanical evaluation of a new pedicle screw-based posterior dynamic stabilization device (Awesome Rod System)--a finite element analysis.

Authors:  Chen-Sheng Chen; Chang-Hung Huang; Shih-Liang Shih
Journal:  BMC Musculoskelet Disord       Date:  2015-04-09       Impact factor: 2.362

4.  Flexible Stabilisation of the Degenerative Lumbar Spine Using PEEK Rods.

Authors:  Jacques Benezech; Bruno Garlenq; Gilles Larroque
Journal:  Adv Orthop       Date:  2016-02-15

5.  Biomechanical Investigation Between Rigid and Semirigid Posterolateral Fixation During Daily Activities: Geometrically Parametric Poroelastic Finite Element Analyses.

Authors:  Mohammad Nikkhoo; Meng-Ling Lu; Wen-Chien Chen; Chen-Ju Fu; Chi-Chien Niu; Yang-Hua Lin; Chih-Hsiu Cheng
Journal:  Front Bioeng Biotechnol       Date:  2021-04-01

6.  Lumbar Fusion With Polyetheretherketone Rods Use for Patients With Degenerative Disease.

Authors:  Donald A Ross; Miner N Ross
Journal:  Fed Pract       Date:  2021-04

7.  Dynamic stabilization for challenging lumbar degenerative diseases of the spine: a review of the literature.

Authors:  Tuncay Kaner; Ali Fahir Ozer
Journal:  Adv Orthop       Date:  2013-04-15

8.  In Vitro Comparison of Dynesys, PEEK, and Titanium Constructs in the Lumbar Spine.

Authors:  Matthew S Yeager; Daniel J Cook; Boyle C Cheng
Journal:  Adv Orthop       Date:  2015-08-17

9.  Non-fusion procedure using PEEK rod systems for lumbar degenerative diseases: clinical experience with a 2-year follow-up.

Authors:  Weimin Huang; Zhengqi Chang; Ruoxian Song; Ke Zhou; Xiuchun Yu
Journal:  BMC Musculoskelet Disord       Date:  2016-02-01       Impact factor: 2.362

10.  Carbon fiber-reinforced PEEK versus titanium implants: an in vitro comparison of susceptibility artifacts in CT and MR imaging.

Authors:  Theresa Krätzig; Klaus C Mende; Malte Mohme; Helge Kniep; Marc Dreimann; Martin Stangenberg; Manfred Westphal; Tobias Gauer; Sven O Eicker
Journal:  Neurosurg Rev       Date:  2020-09-15       Impact factor: 3.042

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.