Literature DB >> 23074167

Patent ductus arteriosus closure using the Amplatzer® vascular plug II for all anatomic variants.

Jeffrey W Delaney1, Scott E Fletcher.   

Abstract

OBJECTIVES: To evaluate the safety and efficacy of the Amplatzer® Vascular Plug II (AVPII) for closure of the patent ductus arteriosus (PDA).
BACKGROUND: The PDA has significant anatomic variation. No device has proven applicable to all PDAs. Previous case reports and small series have documented limited use of the AVPII for some PDA types. We describe the largest and most diverse experience using the AVPII.
METHODS: A retrospective analysis of patients undergoing percutaneous PDA closure between 01/01/2009 and 05/01/2012 was performed. The PDA was characterized, measured, and the device chosen was listed. Deployment technique, complications and procedural results were recorded.
RESULTS: Sixty-seven procedures were performed. The AVPII was utilized for 43 (64.2%), 15 (20.9%) had coils, 7 (10.4%) had the AGA duct occluder, and 3 (4.5%) were referred for surgery. The AVPII was placed in infants as young as 2 months and 4.2 kg. AVPII size ranged from 4 to 10 mm. All PDA types were closed. Retrograde and antegrade deployments were performed, using the outer disc as a "retention skirt" to secure the device and improve occlusion. Three patients were up-sized prior to release. All deployments were successful; 89% "in-lab" and 100% closure on postprocedural echocardiogram. There were no complications.
CONCLUSIONS: We report the largest experience with the AVPII for PDA closure. The device was used in all morphologic types and small patients. It is low profile, easily repositioned, and had excellent results without complications. We contend that this is the most versatile device currently available.
Copyright © 2012 Wiley Periodicals, Inc.

Entities:  

Mesh:

Year:  2012        PMID: 23074167     DOI: 10.1002/ccd.24707

Source DB:  PubMed          Journal:  Catheter Cardiovasc Interv        ISSN: 1522-1946            Impact factor:   2.692


  9 in total

Review 1.  Vascular plugs - A key companion to Interventionists - 'Just Plug it'.

Authors:  Sivasubramanian Ramakrishnan
Journal:  Indian Heart J       Date:  2015-07-26

2.  Combined Retrograde/Antegrade Approach to Transcatheter Closure of an Aortic Paravalvular Leak.

Authors:  Abdulla A Damluji; Husnu E Kaynak; Alan W Heldman
Journal:  Tex Heart Inst J       Date:  2015-10-01

3.  Amplatzer vascular plugs in congenital cardiovascular malformations.

Authors:  Parag Barwad; Sivasubramanian Ramakrishnan; Shyam S Kothari; Anita Saxena; Saurabh K Gupta; Rajnish Juneja; Gurpreet Singh Gulati; Priya Jagia; Sanjiv Sharma
Journal:  Ann Pediatr Cardiol       Date:  2013-07

4.  Percutaneous Patent Ductus Arteriosus (PDA) Closure in Very Preterm Infants: Feasibility and Complications.

Authors:  Carl H Backes; Sharon L Cheatham; Grace M Deyo; Scott Leopold; Molly K Ball; Charles V Smith; Vidu Garg; Ralf J Holzer; John P Cheatham; Darren P Berman
Journal:  J Am Heart Assoc       Date:  2016-02-12       Impact factor: 5.501

5.  Transvenous embolization of moderate to large patent ductus arteriosus in dogs using the Amplatzer vascular plug II.

Authors:  Nicolai Hildebrandt; Andreas Stosic; Estelle Henrich; Nicola Wiedemann; Gabriel Wurtinger; Matthias Schneider
Journal:  J Vet Intern Med       Date:  2021-12-16       Impact factor: 3.333

6.  Transjugular Patent Ductus Arteriosus Occlusion in Seven Dogs Using the Amplatzer Vascular Plug II.

Authors:  Mara Bagardi; Oriol Domenech; Tommaso Vezzosi; Federica Marchesotti; Martina Bini; Valentina Patata; Marta Croce; Valentina Valenti; Luigi Venco
Journal:  Vet Sci       Date:  2022-08-14

7.  Ductal closure using the Amplatzer duct occluder type two: experience in Port Elizabeth hospital complex, South Africa: cardiovascular topic.

Authors:  Lungile Pepeta; Adele Dippenaar
Journal:  Cardiovasc J Afr       Date:  2013-07       Impact factor: 1.167

8.  Outcomes Associated with the Off-label Use of Medical Devices in Congenital Heart Disease at a Single Institute.

Authors:  Young Hwa Kong; Jinyoung Song; Jun Huh; I-Seok Kang
Journal:  Korean Circ J       Date:  2017-07-27       Impact factor: 3.243

9.  Outcomes of transcatheter closure of patent ductus arteriosus with the off-label use of large occluders (≥16 mm).

Authors:  Kewal Kanabar; Dinakar Bootla; Navjyot Kaur; C R Pruthvi; Darshan Krishnappa; Krishna Santosh; Vivek Guleria; Manoj Kumar Rohit
Journal:  Indian Heart J       Date:  2020-04-07
  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.