Literature DB >> 23070933

Standard value of ultrasound elastography using acoustic radiation force impulse imaging (ARFI) in healthy liver tissue of children and adolescents.

J Eiler1, U Kleinholdermann, D Albers, J Dahms, F Hermann, C Behrens, M Luedemann, V Klingmueller, G F P Alzen.   

Abstract

PURPOSE: Ultrasound elastography by acoustic radiation force impulse imaging (ARFI) is used in adults for non invasive measurement of liver stiffness, indicating liver diseases like fibrosis. To establish ARFI in children and adolescents we determined standard values of healthy liver tissue and analysed potentially influencing factors.
MATERIALS AND METHODS: 132 patients between 0 and 17 years old were measured using ARFI. None of them had any liver disease or any other disease that could affect the liver secondarily. All patients had a normal ultrasound scan, a normal BMI and normal liver function tests. The mean value of all ARFI measurements was calculated and potentially influencing factors were analysed.
RESULTS: The mean value of all ARFI elastography measurements was 1.16 m/sec (SD ± 0.14 m/sec). Neither age (p = 0.533) nor depth of measurement (p = 0.066) had no significant influence on ARFI values, whereas a significant effect of gender was found with lower ARFI values in females (p = 0.025), however, there was no significant interaction between age groups (before or after puberty) and gender (p = 0.276). There was an interlobar difference with lower values in the right liver lobe compared to the left (p = 0.036) and with a significantly lower variance (p < 0.001). Consistend values were measured by different examiners (p = 0.108), however, the inter examiner variance deviated significantly (p < 0.001).
CONCLUSION: ARFI elastography is a reliable method to measure liver stiffness in children and adolescents. In relation to studies which analyse liver diseases, the standard value of 1.16 m/sec (± 0.14 m/sec) allows a differentiation of healthy versus pathological liver tissue. © Georg Thieme Verlag KG Stuttgart · New York.

Entities:  

Mesh:

Year:  2012        PMID: 23070933     DOI: 10.1055/s-0032-1313145

Source DB:  PubMed          Journal:  Ultraschall Med        ISSN: 0172-4614            Impact factor:   6.548


  18 in total

1.  Hepatic shear wave elastography in children under free-breathing and breath-hold conditions.

Authors:  Caroline Jung; Michael Groth; Kay Uwe Petersen; Anna Hammel; Florian Brinkert; Enke Grabhorn; Sören Alexander Weidemann; Jasmin Busch; Gerhard Adam; Jochen Herrmann
Journal:  Eur Radiol       Date:  2017-06-20       Impact factor: 5.315

2.  Normal values of liver elasticity measured by real-time tissue elastography (RTE) in healthy infants and children.

Authors:  Buket Selmi; Guido Engelmann; Ulrike Teufel; Saroa El Sakka; Monika Dadrich; Jens-Peter Schenk
Journal:  J Med Ultrason (2001)       Date:  2013-06-11       Impact factor: 1.314

3.  Technical performance of shear wave elastography for measuring liver stiffness in pediatric and adolescent patients: a systematic review and meta-analysis.

Authors:  Dong Wook Kim; Chan Park; Hee Mang Yoon; Ah Young Jung; Jin Seong Lee; Seung Chai Jung; Young Ah Cho
Journal:  Eur Radiol       Date:  2019-01-07       Impact factor: 5.315

4.  Real-time tissue elastography (RTE) for noninvasive evaluation of fibrosis in liver diseases in children in comparison to liver biopsy.

Authors:  Jens-Peter Schenk; Buket Selmi; Christa Flechtenmacher; Saroa El Sakka; Ulrike Teufel; Guido Engelmann
Journal:  J Med Ultrason (2001)       Date:  2014-05-25       Impact factor: 1.314

5.  Shear wave elastography helps differentiate biliary atresia from other neonatal/infantile liver diseases.

Authors:  Jessica R Leschied; Jonathan R Dillman; Jacob Bilhartz; Amer Heider; Ethan A Smith; M James Lopez
Journal:  Pediatr Radiol       Date:  2014-09-20

6.  Measurement of real-time tissue elastography in a phantom model and comparison with transient elastography in pediatric patients with liver diseases.

Authors:  Jens-Peter Schenk; Gerhard Alzen; Volker Klingmüller; Ulrike Teufel; Saroa El Sakka; Guido Engelmann; Buket Selmi
Journal:  Diagn Interv Radiol       Date:  2014 Jan-Feb       Impact factor: 2.630

7.  Effect of Fontan operation on liver stiffness in children with single ventricle physiology.

Authors:  Frank W DiPaola; Kurt R Schumacher; Caren S Goldberg; Joshua Friedland-Little; Aishwarya Parameswaran; Jonathan R Dillman
Journal:  Eur Radiol       Date:  2016-10-17       Impact factor: 5.315

Review 8.  Noninvasive diagnosis of cirrhosis: a review of different imaging modalities.

Authors:  Riccardo De Robertis; Mirko D'Onofrio; Emanuele Demozzi; Stefano Crosara; Stefano Canestrini; Roberto Pozzi Mucelli
Journal:  World J Gastroenterol       Date:  2014-06-21       Impact factor: 5.742

9.  Parameters affecting different acoustic radiation force impulse applications in the diagnosis of fibrotic liver changes.

Authors:  Sabrina Galgenmueller; Heike Jaeger; Wolfgang Kratzer; Stefan A Schmidt; Suemeyra Oeztuerk; Mark M Haenle; Richard A Mason; Tilmann Graeter
Journal:  World J Gastroenterol       Date:  2015-07-21       Impact factor: 5.742

10.  Feasibility study for assessing liver fibrosis in paediatric and adolescent patients using real-time shear wave elastography.

Authors:  Manish Dhyani; Michael S Gee; Joseph Misdraji; Esther Jacobowitz Israel; Uzma Shah; Anthony E Samir
Journal:  J Med Imaging Radiat Oncol       Date:  2015-10-27       Impact factor: 1.735

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.