Abstract

OBJECTIVE: The number of endovascular procedures performed is increasing exponentially as technology improves. A serious complication of endovascular therapy is loss of a foreign body in the vasculature. We reviewed our experience and evaluated the cause, management, and outcomes of intravascular foreign body (IVFB) misplacement.
METHODS: We completed a retrospective review of patients who underwent endovascular retrieval of IVFBs between 2005 and 2010. Patients were identified by current procedural terminology code or by our hospital's risk management team. Patients undergoing routine endovascular retrieval of temporary vena cava filters were excluded.
RESULTS: Twenty-seven IVFBs were identified in 26 patients. Twenty patients were asymptomatic (76.9%). Six patients were symptomatic (22.2%) with either pain (n = 4) or abnormal physical findings (n = 2). There were 13 (48.1%) catheter fragments, six (22.2%) guidewires, five (18.5%) inferior vena cava (IVC) filter (embolisms), two (7.4%) stents, and one (3.7%) sheath fragment. There were five (15.6%) embolizations of an IVFB into the right heart, three (9.4%) into a pulmonary artery, eight (25%) into the vena cava, eight (25%) into peripheral veins, five (15.6%) into peripheral arteries, one (3.1%) into a coronary artery, one (3.1%) into a hepatic vein, and one (3.1%) into adjacent soft tissue. The mechanism of endovascular loss was device fracture in 16 (59.3%) cases, loss of control in six cases (22.2%), migration in four (14.8%) cases, and incorrect device deployment in one case (3.7%). The probable cause of foreign body loss was technical error in eight (29.6%) cases. In three cases, IVFB retrieval was not attempted. The misplacement and retrieval were completed during the same procedure in 13 (48%) cases. Twenty-four endovascular retrievals were performed. Fifteen (62.5%) procedures used a snare to remove the IVFB and two (8.2%) used balloon catheters. Three IVFBs could not be removed and two cases were converted to open procedures. Technical success was achieved in 19/24 cases (79.2%). There were no immediate complications related to the retrieval of the IVFB; however, there was a single late complication of pulmonary embolism after failed endovascular retrieval (1/24, 4.2%). Thirty-day survival was 100%.
CONCLUSIONS: Intravascular foreign bodies are a serious complication of endovascular therapy that can be minimized with proper device selection and deployment. When an intravascular foreign body is identified, endovascular retrieval should be attempted due to its high success rate and minimal morbidity.
Copyright © 2013 Society for Vascular Surgery. Published by Mosby, Inc. All rights reserved.

Entities:  

Mesh:

Year:  2012        PMID: 23069073     DOI: 10.1016/j.jvs.2012.01.092

Source DB:  PubMed          Journal:  J Vasc Surg        ISSN: 0741-5214            Impact factor:   4.268


  19 in total

1.  Foreign body pulmonary embolism.

Authors:  Peter Rief; Klara Belaj; Nicole Smaczny; Michael Augustin; Philipp Eller; Marianne Brodmann; Ernst Pilger
Journal:  Wien Klin Wochenschr       Date:  2013-06-14       Impact factor: 1.704

2.  Transfemoral Technique to Untwist a Knotted Catheter in the Brachial Artery: A Case Report.

Authors:  Nathalie Noirclerc; Paul Alexandru Simion; Abdelkader Bakhti
Journal:  Maedica (Bucur)       Date:  2020-12

3.  Retrieval of distorted pipeline embolic device using snare-loop.

Authors:  Bartley Mitchell; Liang-Der Jou; Michel Mawad
Journal:  J Vasc Interv Neurol       Date:  2014-12

4.  Retrieval of embolized tip of port catheter from branch of right pulmonary artery using a macro snare catheter.

Authors:  Mehmet Bostan; Murtaza Emre Durakoğlugil; Omer Satiroğlu; Başar Erdivanli; Gülnihal Tufan
Journal:  Interv Med Appl Sci       Date:  2014-06-04

5.  A Novel Approach for the Retrieval of Broken Catheter Fragment - Using Balloon Dilatation Technique.

Authors:  Padmakumar Ramachandran; Rohith Poondru Reddy; M Sudhakar Rao; Ashwal Adamane Jayaram
Journal:  J Clin Diagn Res       Date:  2016-03-01

6.  Migration of a fractured inferior vena cava filter strut to the right ventricle of the heart.

Authors:  Zeyad Sako; Sindhu Reddy Avula; Elissa Gaies; Rebecca Daniel
Journal:  BMJ Case Rep       Date:  2018-03-21

7.  Dog-bone inflation to salvage and redeploy a deformed, dislodged expandable stent in the external iliac artery.

Authors:  Wen-Jung Chung; Yasuaki Takeji; Yoshimitsu Soga; Kenji Ando
Journal:  J Cardiol Cases       Date:  2017-11-20

8.  Metallic foreign body in heart mimicking moderator band.

Authors:  Darae Kim; Pil-Sung Yang; Jung-Ho Choi; Jiwon Seo; Kyeong-Hyeon Chun; Sang-Eun Lee; Geu-Ru Hong; Hyun-Chel Joo; Donghoon Choi
Journal:  Yonsei Med J       Date:  2015-05       Impact factor: 2.759

9.  Complex endovascular retrieval of an intravascular foreign body.

Authors:  Tanner I Kim; Valentyna Kostiuk; Dirk Baumann; Edouard Aboian
Journal:  J Vasc Surg Cases Innov Tech       Date:  2021-04-24

10.  Endovascular retrieval of an irrigation cannula from the thoracic aorta following cardiac surgery: A case report.

Authors:  Biju K Thomas; James R Elmore; Robert P Garvin; Evan J Ryer
Journal:  Int J Surg Case Rep       Date:  2015-10-22