Literature DB >> 23067917

Aortic annulus area assessment by multidetector computed tomography for predicting paravalvular regurgitation in patients undergoing balloon-expandable transcatheter aortic valve implantation: a comparison with transthoracic and transesophageal echocardiography.

Gianluca Pontone1, Daniele Andreini, Antonio L Bartorelli, Erika Bertella, Sarah Cortinovis, Saima Mushtaq, Andrea Annoni, Alberto Formenti, Andrea Baggiano, Edoardo Conte, Gloria Tamborini, Manuela Muratori, Paola Gripari, Francesca Bovis, Fabrizio Veglia, Claudia Foti, Francesco Alamanni, Giovanni Ballerini, Cesare Fiorentini, Mauro Pepi.   

Abstract

BACKGROUND: Transcatheter aortic valve implantation (TAVI) is a valid alternative to surgery in high-risk patients with severe aortic stenosis. Aortic annulus (AoA) sizing is crucial for TAVI success. The aim of the study was to compare AoA dimensions measured by multidetector computed tomography (MDCT) vs those obtained with transthoracic (TTE) and transesophageal echocardiography (TEE) for predicting paravalvular aortic regurgitation (PVR) after TAVI.
METHODS: Aortic annulus maximum diameter, minimum diameter, and area were assessed using MDCT and compared with TTE and TEE diameter and area for predicting PVR after TAVI in 151 patients (45 men, age 81.2 ± 6.4 years).
RESULTS: Aortic annulus maximum, minimum diameter, and area detected by MDCT were 25.04 ± 2.39 mm, 21.27 ± 2.10 mm, and 420.87 ± 76.10 mm(2), respectively. Aortic annulus diameter and area measured by TTE and TEE were 21.14 ± 1.94 mm and 353.82 ± 64.57 mm(2) and 22.04 ± 1.94 mm and 384.33 ± 67.30 mm(2), respectively. A good correlation was found between AoA diameters and area evaluated by MDCT vs TTE and TEE (0.61, 0.65, and 0.69 and 0.61, 0.65, and 0.70, respectively), with a mean difference of 3.90 ± 1.98 mm, 0.13 ± 1.67 mm, and 67.05 ± 55.87 mm(2) and 3.0 ± 2.0 mm, 0.77 ± 1.70 mm, and 36.54 ± 56.43 mm(2), respectively. Grade ≥2 PVR occurred in 46 patients and was related to male gender, higher body mass index, preprocedural aortic regurgitation, and lower mismatch between the nominal area of the implanted prosthesis and AoA area detected by MDCT.
CONCLUSIONS: Mismatch between prosthesis area and AoA area detected by MDCT is a better predictor of PVR as compared with echocardiography mismatch. Specific MDCT-based sizing recommendations should be developed.
Copyright © 2012 Mosby, Inc. All rights reserved.

Entities:  

Mesh:

Year:  2012        PMID: 23067917     DOI: 10.1016/j.ahj.2012.06.024

Source DB:  PubMed          Journal:  Am Heart J        ISSN: 0002-8703            Impact factor:   4.749


  10 in total

Review 1.  DNA transposons in vertebrate functional genomics.

Authors:  C Miskey; Z Izsvák; K Kawakami; Z Ivics
Journal:  Cell Mol Life Sci       Date:  2005-03       Impact factor: 9.261

Review 2.  [Aortic valve stenosis: computed tomography prior to transcatheter aortic valve implantation (TAVI). How can the outcome be improved?].

Authors:  M Hell; S Achenbach; M Arnold
Journal:  Herz       Date:  2015-06       Impact factor: 1.443

3.  Optimal pre-TAVR annulus sizing in patients with bicuspid aortic valve: area-derived perimeter by CT is the best-correlated measure with intraoperative sizing.

Authors:  Yuan Wang; Moyang Wang; Guanyuan Song; Wei Wang; Bin Lv; Hao Wang; Yongjian Wu
Journal:  Eur Radiol       Date:  2018-06-20       Impact factor: 5.315

Review 4.  The transition from transesophageal to transthoracic echocardiography during transcatheter aortic valve replacement: an evolving field.

Authors:  Menhel Kinno; Eric P Cantey; Vera H Rigolin
Journal:  J Echocardiogr       Date:  2018-11-21

Review 5.  MRI evaluation prior to Transcatheter Aortic Valve Implantation (TAVI): When to acquire and how to interpret.

Authors:  Abhishek Chaturvedi; Susan K Hobbs; Fred S Ling; Apeksha Chaturvedi; Peter Knight
Journal:  Insights Imaging       Date:  2016-02-25

6.  Impact of different aortic valve calcification patterns on the outcome of transcatheter aortic valve implantation: A finite element study.

Authors:  Francesco Sturla; Mattia Ronzoni; Mattia Vitali; Annalisa Dimasi; Riccardo Vismara; Georgia Preston-Maher; Gaetano Burriesci; Emiliano Votta; Alberto Redaelli
Journal:  J Biomech       Date:  2016-03-25       Impact factor: 2.712

7.  Prognostic value of the ratio between prosthesis area and indexed annulus area measured by MultiSlice-CT for transcatheter aortic valve implantation procedures.

Authors:  Nicolas Debry; Arnaud Sudre; Ibrahim Elquodeimat; Cédric Delhaye; Guillaume Schurtz; Antoine Bical; Mohamad Koussa; Khalil Fattouch; Thomas Modine
Journal:  J Geriatr Cardiol       Date:  2016-09       Impact factor: 3.327

8.  Utility of conventional aortic root shot angiography for SAPIEN 3 prosthesis sizing in TAVI: feasibility and inter-reader variability.

Authors:  Laura Gansera; Bernhard Ulm; Peter Bramlage; Stephan Krapf; Frank Oertel; Tobias Mueller-Honold; Wolfgang von Scheidt; Christian Thilo
Journal:  Open Heart       Date:  2019-12-29

Review 9.  Biomechanics of Transcatheter Aortic Valve Implant.

Authors:  Francesco Nappi; Sanjeet Singh Avtaar Singh; Pierluigi Nappi; Antonio Fiore
Journal:  Bioengineering (Basel)       Date:  2022-07-04

Review 10.  Multimodality Imaging of the Anatomy of the Aortic Root.

Authors:  Vera Lucia Paiocchi; Francesco F Faletra; Enrico Ferrari; Susanne Anna Schlossbauer; Laura Anna Leo; Francesco Maisano
Journal:  J Cardiovasc Dev Dis       Date:  2021-05-04
  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.