Literature DB >> 23065957

A photonic-microfluidic integrated device for reliable fluorescence detection and counting.

Benjamin R Watts1, Zhiyi Zhang, Chang Qing Xu, Xudong Cao, Min Lin.   

Abstract

A photonic-microfluidic integrated device is demonstrated with excellent and reliable fluorescence detection performance. CV values of 8% for 2.5-μm beads and 14% for 6-μm beads were achieved through the correct deployment of carefully formed excitation beam shapes via integrated on-chip optics even without the use of 3D hydrodynamic focusing or a high-quality laser source and single mode beam propagation. The devices are fabricated in a monolithic planar fashion using a system of microlenses and waveguides integrated with microfluidic channels on-chip and packaged using a high-quality and low-cost channel sealing and high-performance interconnecting technology developed from our earlier works. Beam geometry in the excitation region is shown to affect the variation of fluorescence intensity from specimens, hence configurations of beam geometry targeted for a specific bead sizes are examined to ensure proper deployment of the lens designs. The formed high-quality optical excitation regions ensure reliable detection even with relaxed hydrodynamic focusing to ensure applicability with multiple specimen sizes. Device performance with each bead size was found to be acceptable for a range of beam geometries with a different ideal configuration for each bead size. These device designs help to form a device that will supplement conventional flow cytometry in point-of-care and remote detection applications by performing specific detections with an inexpensive and replaceable device.
© 2012 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

Mesh:

Substances:

Year:  2012        PMID: 23065957     DOI: 10.1002/elps.201200311

Source DB:  PubMed          Journal:  Electrophoresis        ISSN: 0173-0835            Impact factor:   3.535


  6 in total

1.  Micro flow cytometer with self-aligned 3D hydrodynamic focusing.

Authors:  Genni Testa; Gianluca Persichetti; Romeo Bernini
Journal:  Biomed Opt Express       Date:  2014-12-08       Impact factor: 3.732

2.  Inertial focusing cytometer with integrated optics for particle characterization.

Authors:  Kenneth T Kotz; Anne C Petrofsky; Ramin Haghgooie; Robert Granier; Mehmet Toner; Ronald G Tompkins
Journal:  Technology (Singap World Sci)       Date:  2013

3.  High performance micro-flow cytometer based on optical fibres.

Authors:  S Etcheverry; A Faridi; H Ramachandraiah; T Kumar; W Margulis; F Laurell; A Russom
Journal:  Sci Rep       Date:  2017-07-17       Impact factor: 4.379

4.  Sheathless Microflow Cytometry Using Viscoelastic Fluids.

Authors:  Mohammad Asghari; Murat Serhatlioglu; Bülend Ortaç; Mehmet E Solmaz; Caglar Elbuken
Journal:  Sci Rep       Date:  2017-09-27       Impact factor: 4.379

Review 5.  Optofluidic Device Based Microflow Cytometers for Particle/Cell Detection: A Review.

Authors:  Yushan Zhang; Benjamin R Watts; Tianyi Guo; Zhiyi Zhang; Changqing Xu; Qiyin Fang
Journal:  Micromachines (Basel)       Date:  2016-04-15       Impact factor: 2.891

6.  A method for detecting forward scattering signals on-chip with a photonic-microfluidic integrated device.

Authors:  Benjamin R Watts; Zhiyi Zhang; Chang-Qing Xu; Xudong Cao; Min Lin
Journal:  Biomed Opt Express       Date:  2013-06-07       Impact factor: 3.732

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.