Impact of heating and air conditioning system operation and leakage on ventilation and intercompartment transport: studies in unoccupied and occupied Tennessee Valley homes.

T G Matthews1, D L Wilson, C V Thompson, K P Monar, C S Dudney.   

Abstract

Forced-air heating and air conditioning (HAC) systems caused an average and maximum increase in air infiltration rates of 1.8- and 4.3-fold, respectively, during brief whole-house studies of tracer gas decay in 39 occupied houses. An average increase in air infiltration rate of 0.33 +/- 0.37 h-1 corresponded to an incremental air leak of 240 m3/h, based on approximate house volume. More detailed tracer gas decay studies were performed in basement, kitchen and bedroom locations of six homes with low air infiltration rates (i.e., less than 0.25 h-1). The HAC mixed the indoor air efficiently between measurement sites. HAC operation also caused 1.1- to 3.6-fold increases in air infiltration rates, corresponding to absolute increases of 0.02 to 0.1 h-1. In an unoccupied research house, three-fold increases in average air infiltration rate with HAC operation (i.e., from 0.13 to 0.36 h-1) were reduced to two-fold (i.e., from 0.10 to 0.18 h-1) by sealing the external HAC unit and crawlspace ductwork system. This sealing also resulted in a 30 percent reduction in crawlspace-to-indoor transport rates with the HAC turned on. Blower door tests indicated a less than 20 percent reduction in house leakage area.

Mesh:

Substances:

Year:  1990        PMID: 2306364     DOI: 10.1080/10473289.1990.10466676

Source DB:  PubMed          Journal:  J Air Waste Manage Assoc        ISSN: 1047-3289


  1 in total

1.  Spatial and temporal distribution of airborne Bacillus thuringiensis var. kurstaki during an aerial spray program for gypsy moth eradication.

Authors:  K Teschke; Y Chow; K Bartlett; A Ross; C van Netten
Journal:  Environ Health Perspect       Date:  2001-01       Impact factor: 9.031

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.