Literature DB >> 23063209

Comparison of a 3-hour versus a 6-hour sampling-protocol using high-sensitivity cardiac troponin T for rule-out and rule-in of non-STEMI in an unselected emergency department population.

Moritz Biener1, Matthias Mueller, Mehrshad Vafaie, Till Keller, Stefan Blankenberg, Harvey D White, Hugo A Katus, Evangelos Giannitsis.   

Abstract

BACKGROUND: Current European guidelines recommend the use of sensitive or high-sensitivity cardiac troponin assays to reduce the minimal sampling interval from 6 to 3h.
METHODS: We compared a 3-hour versus a 6-hour protocol for diagnosis of non-STEMI and used the 99th percentile for rule-out, and relative and absolute concentration changes for rule-in of non-STEMI.
RESULTS: 459 patients with either an NSTE-ACS or elevated hs-cTnT not due to MI and hs-cTnT measurements at 0, 3 and 6h were enrolled. Among the 404 patients excluded due to an incomplete sampling protocol performance was comparable to the 459 patients with a complete sampling protocol (AUC 0.79 vs 0.80, p=ns). In the study group, non-STEMI was diagnosed in 111 cases (24.2%) and elevated hs-cTnT not due to MI was observed in 215 cases (46.8%). For rule-out of non-STEMI, NPVs were 94.9%, 98.7% and 100% on admission, at 3 and 6h with comparable performance at 3 and 6h (AUC 0.782 vs 0.790, p=ns). For rule-in a 3-hour protocol performed as well as a 6-hour protocol, with a significantly (p<0.0001) better performance of absolute (AUC 0.851 vs. 0.845, p=0.740) as compared to relative concentration changes (AUC 0.771 vs. 0.739, p=0.169).
CONCLUSIONS: Rule-in and rule-out of non-STEMI may be accomplished comparably effective at 3 or 6h. For rule-in, absolute kinetic changes perform better than relative changes at all time points. ROC-optimal absolute δ-change was 6.95 ng/L at 3h and 8.9 ng/L at 6h.
Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.

Entities:  

Keywords:  Diagnostic performance; High-sensitivity troponin T; Non-STEMI; Serial changes

Mesh:

Substances:

Year:  2012        PMID: 23063209     DOI: 10.1016/j.ijcard.2012.09.122

Source DB:  PubMed          Journal:  Int J Cardiol        ISSN: 0167-5273            Impact factor:   4.164


  12 in total

Review 1.  The evolving role of cardiac troponin in the evaluation of cardiac disorders.

Authors:  Paul Anaya; David J Moliterno
Journal:  Curr Cardiol Rep       Date:  2013-11       Impact factor: 2.931

Review 2.  "Troponin elevation in coronary ischemia and necrosis".

Authors:  Stefan Agewall; Evangelos Giannitsis
Journal:  Curr Atheroscler Rep       Date:  2014-03       Impact factor: 5.113

3.  Typical rise and fall of troponin in (peri-procedural) myocardial infarction: A systematic review.

Authors:  Dianne van Beek; Bas van Zaane; Marjolein Looije; Linda Peelen; Wilton van Klei
Journal:  World J Cardiol       Date:  2016-03-26

Review 4.  Diagnostic algorithms for acute coronary syndrome-is one better than another?

Authors:  Gianfranco Cervellin; Camilla Mattiuzzi; Chiara Bovo; Giuseppe Lippi
Journal:  Ann Transl Med       Date:  2016-05

Review 5.  Revisiting the Biological Variability of Cardiac Troponin: Implications for Clinical Practice.

Authors:  Nick S R Lan; Damon A Bell
Journal:  Clin Biochem Rev       Date:  2019-11

Review 6.  Universal MI definition update for cardiovascular disease.

Authors:  Harvey White; Kristian Thygesen; Joseph S Alpert; Allan Jaffe
Journal:  Curr Cardiol Rep       Date:  2014       Impact factor: 2.931

7.  The change in high-sensitivity troponin-T as a risk factor for significant coronary stenosis in patients with acute coronary syndrome.

Authors:  Min Chul Kim; Seok Oh; Youngkeun Ahn; Keumyi Moon; Joon Ho Ahn; Dae Young Hyun; Kyung Hoon Cho; Doo Sun Sim; Young Joon Hong; Ju Han Kim; Myung Ho Jeong; Jeong Gwan Cho; Jong Chun Park
Journal:  Korean J Intern Med       Date:  2021-01-04       Impact factor: 2.884

Review 8.  Diagnostic accuracy of single baseline measurement of Elecsys Troponin T high-sensitive assay for diagnosis of acute myocardial infarction in emergency department: systematic review and meta-analysis.

Authors:  Zhivko Zhelev; Christopher Hyde; Emily Youngman; Morwenna Rogers; Simon Fleming; Toby Slade; Helen Coelho; Tracey Jones-Hughes; Vasilis Nikolaou
Journal:  BMJ       Date:  2015-01-20

9.  How rapid is rapid? Exemplary results of real-life rapid rule-out troponin timing in troponin-positive acute coronary syndromes without persistent ST-segment elevation in two contrasting German chest pain unit facilities.

Authors:  Dieter Fischer; Friederike Remberg; Dirk Böse; Michael Lichtenberg; Philipp Kümpers; Pia Lebiedz; Hermann-Joseph Pavenstädt; Johannes Waltenberger; Frank Breuckmann
Journal:  Eur J Med Res       Date:  2016-03-17       Impact factor: 2.175

10.  Measurement of cardiac troponins to detect myocardial infarction using high-sensitivity assays: South African guidelines.

Authors:  R Delport; J A Ker
Journal:  Cardiovasc J Afr       Date:  2012-11       Impact factor: 1.167

View more