Literature DB >> 23062958

Influence of miniscrew dental root proximity on its degree of late stability.

G Janson1, M P Gigliotti, S Estelita, K Chiqueto.   

Abstract

Purpose of this study was to evaluate the influence of miniscrew dental root proximity on its late stability degree. 40 miniscrews were inserted between maxillary second premolars and first molars for anterior retraction. Post-surgical radiographs were used to measure the septum width in the insertion site, insertion height, distal and mesial distance from miniscrew to dental root, and the smallest distance between miniscrew and dental root. The miniscrews were divided in two groups according to septum width: ≤3 mm (20 miniscrews) and >3 mm (20 miniscrews). The soft tissue in the insertion site, sensitivity during load, plaque around the miniscrew, and evaluation period were also considered. The results showed no significant difference in miniscrew mobility degree and success rate between groups. Miniscrew dental root proximity did not influence the stability and success rate when the distance between the miniscrew and dental root indicated no periodontal ligament invasion. The overall success rate was 90% and no variable was associated with miniscrew failure. Nevertheless, patient sensitivity was frequently associated with some degree of mini-implant mobility. The septum width did not influence the stability and success rate of this anchorage system, but the extreme root proximity did.
Copyright © 2012 International Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.

Entities:  

Mesh:

Year:  2012        PMID: 23062958     DOI: 10.1016/j.ijom.2012.09.010

Source DB:  PubMed          Journal:  Int J Oral Maxillofac Surg        ISSN: 0901-5027            Impact factor:   2.789


  8 in total

Review 1.  A Scoping Review about the Characteristics and Success-Failure Rates of Temporary Anchorage Devices in Orthodontics.

Authors:  Daniel Jaramillo-Bedoya; Gustavo Villegas-Giraldo; Andrés A Agudelo-Suárez; Diana Milena Ramírez-Ossa
Journal:  Dent J (Basel)       Date:  2022-05-06

2.  Effect of recycling protocol on mechanical strength of used mini-implants.

Authors:  Sérgio Estelita; Guilherme Janson; Kelly Chiqueto; Eduardo Silveira Ferreira
Journal:  Int J Dent       Date:  2014-07-17

3.  Three-dimensional evaluation of maxillary anterior alveolar bone for optimal placement of miniscrew implants.

Authors:  Jin Hwan Choi; Hyung Seog Yu; Kee Joon Lee; Young Chel Park
Journal:  Korean J Orthod       Date:  2014-03-19       Impact factor: 1.372

4.  A simple three-dimensional stent for proper placement of mini-implant.

Authors:  A Sumathi Felicita
Journal:  Prog Orthod       Date:  2013-11-12       Impact factor: 2.750

5.  Reader's Forum.

Authors:  Seung-Pyo Lee
Journal:  Korean J Orthod       Date:  2014-09       Impact factor: 1.372

6.  Role of anatomical sites and correlated risk factors on the survival of orthodontic miniscrew implants: a systematic review and meta-analysis.

Authors:  Hisham Mohammed; Khaled Wafaie; Mumen Z Rizk; Mohammed Almuzian; Rami Sosly; David R Bearn
Journal:  Prog Orthod       Date:  2018-09-24       Impact factor: 2.750

7.  Histomorphometric evaluation of the bone surrounding orthodontic miniscrews according to their adjacent root proximity.

Authors:  Hyun-Ju Oh; Jung-Yul Cha; Hyung-Seog Yu; Chung-Ju Hwang
Journal:  Korean J Orthod       Date:  2018-08-08       Impact factor: 1.372

Review 8.  Efficacy of orthodontic mini implants for en masse retraction in the maxilla: a systematic review and meta-analysis.

Authors:  Kathrin Becker; Annika Pliska; Caroline Busch; Benedict Wilmes; Michael Wolf; Dieter Drescher
Journal:  Int J Implant Dent       Date:  2018-10-25
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.