Implant stability and bone remodeling after 3 and 13 days of implantation with an initial static strain.

Anders Halldin1, Ryo Jimbo, Carina B Johansson, Ann Wennerberg, Magnus Jacobsson, Tomas Albrektsson, Stig Hansson.   

Abstract

OBJECTIVE: Bone is constantly exposed to dynamic and static loads, which induce both dynamic and static bone strains. Although numerous studies exist on the effect of dynamic strain on implant stability and bone remodeling, the effect of static strain needs further investigation. Therefore, the effect of two different static bone strain levels on implant stability and bone remodeling at two different implantation times was investigated in a rabbit model.
METHODS: Two different test implants with a diametrical expansion of 0.15 mm (group A) and 0.05 mm (group B) creating initial static bone strains of 0.045 and 0.015, respectively. The implants were inserted in the proximal tibial metaphysis of 24 rabbits to observe the biological response at implant removal. Both groups were compared to control implants (group C), with no diametrical increase. The insertion torque (ITQ) was measured to represent the initial stability and the removal torque (RTQ) was measured to analyze the effect that static strain had on implant stability and bone remodeling after 3 and 13 days of implantation time.
RESULTS: The ITQ and the RTQ values for test implants were significantly higher for both implantation times compared to control implants. A selection of histology samples was prepared to measure bone to implant contact (BIC). There was a tendency that the BIC values for test implants were higher compared to control implants.
CONCLUSION: These findings suggest that increased static bone strain creates higher implant stability at the time of insertion, and this increased stability is maintained throughout the observed period.
© 2012 Wiley Periodicals, Inc.

Entities:  

Keywords:  animal model; bone resorption; implant stability

Mesh:

Substances:

Year:  2012        PMID: 23061968     DOI: 10.1111/cid.12000

Source DB:  PubMed          Journal:  Clin Implant Dent Relat Res        ISSN: 1523-0899            Impact factor:   3.932


  3 in total

1.  Simulation of the mechanical interlocking capacity of a rough bone implant surface during healing.

Authors:  Anders Halldin; Mats Ander; Magnus Jacobsson; Stig Hansson
Journal:  Biomed Eng Online       Date:  2015-05-21       Impact factor: 2.819

2.  Can changes in implant macrogeometry accelerate the osseointegration process?: An in vivo experimental biomechanical and histological evaluations.

Authors:  Sergio Alexandre Gehrke; Jaime Aramburú; Leticia Pérez-Díaz; Tales Dias do Prado; Berenice Anina Dedavid; Patricia Mazon; Piedad N De Aza
Journal:  PLoS One       Date:  2020-05-14       Impact factor: 3.240

3.  Implant stability and bone remodeling up to 84 days of implantation with an initial static strain. An in vivo and theoretical investigation.

Authors:  Anders Halldin; Yohei Jinno; Silvia Galli; Mats Ander; Magnus Jacobsson; Ryo Jimbo
Journal:  Clin Oral Implants Res       Date:  2016-01-14       Impact factor: 5.977

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.