Literature DB >> 23061397

Assessment of block height for satisfactory spinal anaesthesia for caesarean section.

R Ousley1, C Egan, K Dowling, A M Cyna.   

Abstract

We investigated block heights that anaesthetists considered adequate for caesarean section to proceed under spinal anaesthesia. During 3 months, 15 obstetric anaesthetists recorded block height to touch, pinprick or cold when spinal anaesthesia was considered satisfactory for caesarean section to proceed. Median (IQR [range]) block height for touch, pinprick, first cold and icy were: T10 (T7-T12 [T3-L1]); T5 (T4-T6 [C7-L1]); T5 (T4-T6 [C7-L1]); and T3 (T2-T4 [C7-L1]), respectively. Modalities were significantly correlated for: touch and cold, p = 0.0001; touch and icy, p = 0.0007; touch and pinprick, p = 0.0018; cold and icy, p < 0.0001; cold and pinprick, p = 0.0001; icy and pinprick, p < 0.0001. Pairwise comparisons showed differences between all modalities (p < 0.001) apart from pinprick and first cold (p = 0.94). All women had satisfactory anaesthesia despite 76 (81%) having a block to touch below T6. Single modality assessment of block height, particularly using touch, may erroneously indicate inadequate anaesthesia for caesarean section. Anaesthesia
© 2012 The Association of Anaesthetists of Great Britain and Ireland.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 23061397     DOI: 10.1111/anae.12034

Source DB:  PubMed          Journal:  Anaesthesia        ISSN: 0003-2409            Impact factor:   6.955


  16 in total

1.  Comparison of spinal anaesthesia with isobaric chloroprocaine and general anaesthesia for short duration ambulatory urological procedures.

Authors:  Siddarth Ravi; Handattu M Krishna
Journal:  J Anaesthesiol Clin Pharmacol       Date:  2022-02-10

2.  Does Adding Lidocaine to Intrathecal Bupivacaine Affect Hemodynamic Parameters during Hip Fracture Surgery?

Authors:  Abbas Sedighinejad; Bahram Naderi Nabi; Hossein Ettehad; Ahmadreza Mirbolook; Zahra Atrkarroushan; Samaneh Ghazanfar Tehran; Gelareh Biazar; Mohammad Haghighi
Journal:  Arch Bone Jt Surg       Date:  2018-09

3.  Evaluation of the accuracy of vibration sense with VibraTip™ as a tool to determine the level of anesthesia following subarachnoid block and its correlation with the pinprick sensation.

Authors:  Sangineni Kalyani Surya Dhana Lakshmi; C Kasavanesi Ramakrishna; Dasari SatyaSree; P Vangala Prakash
Journal:  J Anaesthesiol Clin Pharmacol       Date:  2021-04-10

4.  Techniques for preventing hypotension during spinal anaesthesia for caesarean section.

Authors:  Cheryl Chooi; Julia J Cox; Richard S Lumb; Philippa Middleton; Mark Chemali; Richard S Emmett; Scott W Simmons; Allan M Cyna
Journal:  Cochrane Database Syst Rev       Date:  2020-07-01

5.  Abdominal girth and vertebral column length aid in predicting intrathecal hyperbaric bupivacaine dose for elective cesarean section.

Authors:  Chang-Na Wei; Qing-He Zhou; Li-Zhong Wang
Journal:  Medicine (Baltimore)       Date:  2017-08       Impact factor: 1.889

6.  A study to compare caudal levobupivacaine, tramadol and a combination of both in paediatric inguinal hernia surgeries.

Authors:  Neelam Dogra; Rajat Dadheech; Mahipal Dhaka; Anupama Gupta
Journal:  Indian J Anaesth       Date:  2018-05

7.  The use of tenoxicam to prevent symptoms of discomfort induced by vagotonia during uterus manipulation in cesarean sections.

Authors:  Shih-Hong Chen; Shiou-Sheng Chen; Ching-Tao Chang; Chi-Hsiang Huang; Shou-Zen Fan; Li-Kuei Chen
Journal:  Medicine (Baltimore)       Date:  2017-07       Impact factor: 1.889

8.  Repeat spinal anesthesia in cesarean section: A comparison between 10 mg and 12 mg doses of intrathecal hyperbaric (0.05%) bupivacaine repeated after failed spinal anesthesia: A prospective, parallel group study.

Authors:  Debasish Bhar; Sandip RoyBasunia; Anjan Das; Subinay Chhaule; Sudipta Kumar Mondal; Subrata Bisai; Surajit Chattopadhyay; Subrata Kumar Mandal
Journal:  Anesth Essays Res       Date:  2016 May-Aug

9.  Comparing the Effect of Adding Fentanyl, Sufentanil, and Placebo with Intrathecal Bupivacaine on Duration of Analgesia and Complications of Spinal Anesthesia in Patients Undergoing Cesarean Section.

Authors:  Farnoush Farzi; Ali Mirmansouri; Bahram Naderi Nabi; Zahra Atrkar Roushan; Samaneh Ghazanfar Tehran; Mona Nematollahi Sani; Soodabe Makhlooghi Azad; Maryam Nemati
Journal:  Anesth Pain Med       Date:  2017-08-27

10.  The effect of parturient height on the median effective dose of intrathecally administered ropivacaine.

Authors:  Xiangdi Yu; Fangxiang Zhang
Journal:  Ann Saudi Med       Date:  2016 Sep-Oct       Impact factor: 1.526

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.