Literature DB >> 23060343

Application of implantable wireless biomicrosystem for monitoring nerve impedance of rat after sciatic nerve injury.

Yu-Ting Li1, Chih-Wei Peng, Lung-Tai Chen, Wen-Shan Lin, Chun-Hsun Chu, Jia-Jin Jason Chen.   

Abstract

Electrical stimulation is usually applied percutaneously for facilitating peripheral nerve regeneration. However, few studies have conducted long-term monitoring of the condition of nerve regeneration. This study implements an implantable biomicrosystem for inducing pulse current for aiding nerve repair and monitoring the time-course changes of nerve impedance for assessing nerve regeneration in sciatic nerve injury rat model. For long-term implantation, a transcutaneous magnetic coupling technique is adopted for power and data transmission. For in vivo study, the implanted module was placed in the rat's abdomen and the cuff electrode was wrapped around an 8-mm sciatic nerve gap of the rat for nerve impedance measurement for 42 days. One group of animals received monophasic constant current via the cuff electrode and a second group had no stimulation between days 8-21. The nerve impedance increased to above 150% of the initial value in the nerve regeneration groups with and without stimulation whereas the group with no nerve regeneration increased to only 113% at day 42. The impedance increase in nerve regeneration groups can be observed before evident functional recovery. Also, the nerve regeneration group that received electrical stimulation had relatively higher myelinated fiber density than that of no stimulation group, 20686 versus 11417 fiber/mm (2). The developed implantable biomicrosystem is proven to be a useful experimental tool for long-term stimulation in aiding nerve fiber growth as well as impedance assessment for understanding the time-course changes of nerve regeneration.

Entities:  

Mesh:

Year:  2012        PMID: 23060343     DOI: 10.1109/TNSRE.2012.2219883

Source DB:  PubMed          Journal:  IEEE Trans Neural Syst Rehabil Eng        ISSN: 1534-4320            Impact factor:   3.802


  4 in total

1.  Bio-impedance characterization technique with implantable neural stimulator using biphasic current stimulus.

Authors:  Yi-Kai Lo; Chih-Wei Chang; Wentai Liu
Journal:  Conf Proc IEEE Eng Med Biol Soc       Date:  2014

2.  Designing and Implementing an Implantable Wireless Micromanometer System for Real-Time Bladder Pressure Monitoring: A Preliminary Study.

Authors:  Yu-Ting Li; Ling-Yu Yang; Wei-Ting Hsu; Chih-Wei Peng
Journal:  Sensors (Basel)       Date:  2020-08-17       Impact factor: 3.576

3.  Bio-impedance method to monitor colon motility response to direct distal colon stimulation in anesthetized pigs.

Authors:  Yushan Wang; Po-Min Wang; Muriel Larauche; Million Mulugeta; Wentai Liu
Journal:  Sci Rep       Date:  2022-08-12       Impact factor: 4.996

Review 4.  Restoration of Neurological Function Following Peripheral Nerve Trauma.

Authors:  Damien P Kuffler; Christian Foy
Journal:  Int J Mol Sci       Date:  2020-03-06       Impact factor: 5.923