Literature DB >> 23060253

Frequency weighting for vibration-induced white finger compatible with exposure-response models.

Anthony J Brammer1, Paul M Pitts.   

Abstract

An analysis has been performed to derive a frequency weighting for the development of vibration-induced white finger (VWF). It employs a model to compare health risks for pairs of population groups that are selected to have similar health outcomes from operating power tools or machines with markedly different acceleration spectra (rock drills, chain saws, pavement breakers and motorcycles). The model defines the Relative Risk, RR(f(trial)), which is constructed from the ratio of daily exposures and includes a trial frequency weighting that is applied to the acceleration spectra. The trial frequency weighting consists of a frequency-independent primary frequency range, and subordinate frequency ranges in which the response to vibration diminishes, with cut-off frequencies that are changed to influence the magnitude of RR(f(trial)). The frequency weighting so derived when RR(f(trial)) = 1 is similar to those obtained by other methods (W(hf), W(hT)). It consists of a frequency independent range from about 25 Hz to 500 Hz (-3 dB frequencies), with an amplitude cut-off rate of 12 dB/octave below 25 Hz and above 500 Hz. The range is compatible with studies of vasoconstriction in persons with VWF. The results provide further evidence that the ISO frequency weighting may be inappropriate for assessing the risk of developing VWF.

Entities:  

Mesh:

Year:  2012        PMID: 23060253     DOI: 10.2486/indhealth.ms1383

Source DB:  PubMed          Journal:  Ind Health        ISSN: 0019-8366            Impact factor:   2.179


  4 in total

1.  Reduction in finger blood flow induced by hand-transmitted vibration: effect of hand elevation.

Authors:  Ying Ye; Marcella Mauro; Massimo Bovenzi; Michael J Griffin
Journal:  Int Arch Occup Environ Health       Date:  2015-02-08       Impact factor: 3.015

2.  Relation between vibrotactile perception thresholds and reductions in finger blood flow induced by vibration of the hand at frequencies in the range 8-250 Hz.

Authors:  Ying Ye; Michael J Griffin
Journal:  Eur J Appl Physiol       Date:  2014-04-29       Impact factor: 3.078

3.  Tremor and hand-arm vibration syndrome (HAVS) in road maintenance workers.

Authors:  Rita Bast-Pettersen; Bente Ulvestad; Karl Færden; Thomas Aleksander C Clemm; Raymond Olsen; Dag Gunnar Ellingsen; Karl-Christian Nordby
Journal:  Int Arch Occup Environ Health       Date:  2016-10-28       Impact factor: 3.015

4.  Vibration and Noise Transmitted by Agricultural Backpack Powered Machines Critically Examined Using the Current Standards.

Authors:  Angela Calvo; Christian Preti; Maria Caria; Roberto Deboli
Journal:  Int J Environ Res Public Health       Date:  2019-06-21       Impact factor: 3.390

  4 in total