A comparison of coagulation study results between heparinized peripherally inserted central catheters and venipunctures.

Linda Humphries1, Kathleen M Baldwin, Kirstena L Clark, Vivian Tenuta, Kimberly Brumley.   

Abstract

PURPOSE/
OBJECTIVE: The purpose of this study was to test an evidence-based procedure of drawing blood samples for coagulation testing from heparinized peripherally inserted central catheter (PICC) by comparing results with blood drawn from venipuncture (VP).
DESIGN: A prospective, quasi-experimental design using purposive sampling was used.
SETTING: The setting was a 230-bed community hospital located in the Southwest. The hospital is part of a 15-hospital system. SAMPLE: : The sample was composed of 30 hospitalized patients with heparinized PICCs.
METHODS: Informed consent was obtained. Using aseptic technique, samples of blood were drawn via VP and from the PICC using the evidence-based procedure. Data were analyzed using Pearson product moment correlations and Bland-Altman analysis.
FINDINGS: For 5 coagulation tests studied, correlations between PICC values and VP values ranged from 0.990 to 0.998, indicating almost perfect correlations. In Bland-Altman analyses, mean biases and SDs were small to moderate for prothrombin time, 0.13 seconds (-0.55 to 0.81 seconds) (P = 0.0484); international normalized ratio, 0.010 (-0.050 to 0.070) (P = 0.085); partial thromboplastin time, 2.16 seconds (-5.10 to 9.43 seconds) (P = 0.0033); and fibrinogen, -18.2 mg (-70.4 to 34.1 mg) (P = 0.0033) and 0.52 (-0.73 to 1.77) seconds (P = 0.0003). Correlations of absolute difference versus average ranged from 0.18 to 0.49. Only the paired international normalized ratio samples had P values suggesting nonagreement.
CONCLUSIONS: Drawing blood samples from heparinized PICCs for coagulation tests using the evidence-based procedure developed for this study resulted in accurate coagulation test results in 4 of the 5 tests: prothrombin time, partial thromboplastin time, and fibrinogen in seconds and in milligrams.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 23059715     DOI: 10.1097/NUR.0b013e31826e3efb

Source DB:  PubMed          Journal:  Clin Nurse Spec        ISSN: 0887-6274            Impact factor:   1.067


  2 in total

1.  A Standard Push-Pull Protocol for Waste-Free Sampling in the Pediatric Intensive Care Unit.

Authors:  Clare McBride; Suzan Miller-Hoover; James A Proudfoot
Journal:  J Infus Nurs       Date:  2018 May/Jun

2.  Accuracy of laboratory tests drawn by pull-push method from central venous catheterization after routine flushing with 10 ml normal saline in patients with sepsis at the emergency department.

Authors:  Thanin Lokeskrawee; Sombat Muengtaweepongsa; Jayanton Patumanond; Chutinun Sawaengrat
Journal:  Heliyon       Date:  2021-06-23
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.