Literature DB >> 23057141

Radiographic sizing for meniscal transplantation using 3-D CT reconstruction.

Mark McConkey1, Craig Lyon, D Lee Bennett, Bradley Schoch, Carla Britton, Annunziato Amendola, Brian Wolf.   

Abstract

In meniscus transplantation, allograft size mismatch causes increased contact pressures and early degeneration of the knee. The purpose of this study is to compare the accuracy and reliability of sizing the tibial plateau using three-dimensional (3-D) computed tomography (CT) scans versus plain radiographs (XR). Anteroposterior (AP) and lateral XR as well as CT with 3-D reconstructions were performed on 16 cadaveric knees. Sagittal and coronal dimensions of the hemiplateaus were measured on each imaging modality and then on the disarticulated specimens. CT estimates of plateau size were closer to anatomic measurements compared with radiographic estimates in all dimensions and these differences were statistically significant (p < 0.0001). CT scan fell within 5 mm of anatomic measurements 100% of the time versus 76.5% for XR and within 2 mm 71.9% of the time versus 34.4%. The proportion of CT measurements within 2 mm of actual values was significantly higher for CT for the lateral meniscus on AP (p = 0.0011) and lateral (p = 0.0039) views. 3-D CT has less error in measurement of the tibial plateau than XR and estimates were more likely to be within 2 and 5 mm of actual size. This may decrease the likelihood of allograft size mismatch.

Mesh:

Year:  2012        PMID: 23057141     DOI: 10.1055/s-0031-1292651

Source DB:  PubMed          Journal:  J Knee Surg        ISSN: 1538-8506            Impact factor:   2.757


  6 in total

Review 1.  Meniscal allograft transplantation. Part 1: systematic review of graft biology, graft shrinkage, graft extrusion, graft sizing, and graft fixation.

Authors:  Gonzalo Samitier; Eduard Alentorn-Geli; Dean C Taylor; Brian Rill; Terrence Lock; Vasilius Moutzouros; Patricia Kolowich
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2014-09-27       Impact factor: 4.342

Review 2.  A systematic review of the incidence and clinical significance of postoperative meniscus transplant extrusion.

Authors:  Frank R Noyes; Sue D Barber-Westin
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2014-09-24       Impact factor: 4.342

3.  Should the meniscal height be considered for preoperative sizing in meniscal transplantation?

Authors:  Alfredo Dos Santos Netto; Camila Cohen Kaleka; Mariana Kei Toma; Julio Cesar de Almeida E Silva; Ricardo de Paula Leite Cury; Patricia Maria de Moraes Barros Fucs; Nilson Roberto Severino
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2017-02-23       Impact factor: 4.342

4.  Clinical and radiologic outcomes after a modified bone plug technique with anatomical meniscal root reinsertion for meniscal allograft transplantation and a minimum 18-month follow-up.

Authors:  Shiyou Ren; Xintao Zhang; Tian You; Xiaocheng Jiang; Dadi Jin; Wentao Zhang
Journal:  J Orthop Surg Res       Date:  2018-04-24       Impact factor: 2.359

Review 5.  Meniscus allograft transplantation: indications, techniques and outcomes.

Authors:  Francisco Figueroa; David Figueroa; Rafael Calvo; Alex Vaisman; João Espregueira-Mendes
Journal:  EFORT Open Rev       Date:  2019-04-25

6.  Three-dimensional meniscus allograft sizing-a study of 280 healthy menisci.

Authors:  Silvan Beeler; Lukas Jud; Marco von Atzigen; Reto Sutter; Philipp Fürnstahl; Sandro F Fucentese; Lazaros Vlachopoulos
Journal:  J Orthop Surg Res       Date:  2020-02-24       Impact factor: 2.359

  6 in total