Changes in the fractal dimension, feret diameter, and lacunarity of mandibular alveolar bone during initial healing of dental implants.

Erinç Önem1, B Güniz Baksı, Elif Sogur.   

Abstract

PURPOSE: To evaluate the combination of fractal dimension (FD), lacunarity, and Feret diameter (FeD) to quantitatively characterize structural changes of mandibular alveolar bone around dental implants during initial healing.
MATERIALS AND METHODS: Three standard-sized regions of interest (ROIs) (mesial and distal crest and apical area) around implants and three ROIs of the same size in the alveolar bone on the contralateral side were analyzed on digital panoramic images. FD was calculated using the box-counting method, and lacunarity was calculated using the FracLac plugin of Image J software. FeD was measured in the same ROIs. Comparisons of the groups were done with the Dunnett test.
RESULTS: Forty-two implants in the posterior mandibles of 21 patients were used for FD measurements. A total of 189 ROIs was segmented into binary images. Mean FD values for mesial, distal, and apical ROIs around implants were 1.26, 1.36, and 1.4, respectively. The mean FD of alveolar bone around premolars/molars was 1.39 for all ROIs. The mean FeD for mesial, distal, and apical ROIs around implants was 7.63, 7.86, and 8.02, respectively, whereas it ranged between 7.88 and 8.13 for premolar teeth. Mean lacunarity values for mesial, distal, and apical ROIs around implants were 0.53, 0.51, and 0.48, respectively. Lacunarity values for ROIs around premolars ranged between 0.45 and 0.50. No significant differences were observed in FD, FeD, or lacunarity measurements between ROIs around implants and around teeth.
CONCLUSIONS: The satisfactory healing of bone following implant placement may be monitored by calculating FD, lacunarity, and FeD using digital panoramic images. Although preliminary, these values may alert the practitioner to any implants with loss of stability.

Entities:  

Mesh:

Year:  2012        PMID: 23057012

Source DB:  PubMed          Journal:  Int J Oral Maxillofac Implants        ISSN: 0882-2786            Impact factor:   2.804


  4 in total

1.  Use of fractal analysis in dental images: a systematic review.

Authors:  Camila Nao Kato; Sâmila G Barra; Núbia Pk Tavares; Tânia Mp Amaral; Cláudia B Brasileiro; Ricardo A Mesquita; Lucas G Abreu
Journal:  Dentomaxillofac Radiol       Date:  2019-08-20       Impact factor: 2.419

2.  Bone Texture Fractal Dimension Analysis of Ultrasound-Treated Bone around Implant Site: A Double-Blind Clinical Trial.

Authors:  Elaf Akram Abdulhameed; Natheer Hashim Al-Rawi; Asmaa Tahseen Uthman; Ab Rani Samsudin
Journal:  Int J Dent       Date:  2018-04-15

3.  A comparison of four different imaging modalities - Conventional, cross polarized, infra-red and ultra-violet in the assessment of childhood bruising.

Authors:  L Trefan; C Harris; S Evans; D Nuttall; S Maguire; A M Kemp
Journal:  J Forensic Leg Med       Date:  2018-08-04       Impact factor: 1.614

Review 4.  Fractal Dimension as a Tool for Assessment of Dental Implant Stability-A Scoping Review.

Authors:  Sukanya Mishra; Manoj Kumar; Lora Mishra; Rinkee Mohanty; Rashmita Nayak; Abhaya Chandra Das; Sambhab Mishra; Saurav Panda; Barbara Lapinska
Journal:  J Clin Med       Date:  2022-07-13       Impact factor: 4.964

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.