Literature DB >> 23055412

Dye free automated cell counting and analysis.

Dietrich Dehlinger1, Lynn Suer, Maher Elsheikh, José Peña, Pejman Naraghi-Arani.   

Abstract

We have developed an automated cell counting method that uses images obtained at multiple focal heights to enumerate cells in confluent culture. By taking the derivative of image intensity with respect to focal height using two complementary images, we are able to count high-density monolayers of cells over a large image area. Our method resists errors arising from variability in the focal plane caused by flatness or tilt non-uniformities with a minimal amount of focal plane alignment, allowing the automated collection of images across a large area.
Copyright © 2013 Wiley Periodicals, Inc.

Entities:  

Mesh:

Year:  2013        PMID: 23055412     DOI: 10.1002/bit.24757

Source DB:  PubMed          Journal:  Biotechnol Bioeng        ISSN: 0006-3592            Impact factor:   4.530


  6 in total

1.  Semi-quantitative monitoring of confluence of adherent mesenchymal stromal cells on calcium-phosphate granules by using widefield microscopy images.

Authors:  Filippo Piccinini; Michela Pierini; Enrico Lucarelli; Alessandro Bevilacqua
Journal:  J Mater Sci Mater Med       Date:  2014-05-28       Impact factor: 3.896

2.  Counting unstained, confluent cells by modified bright-field microscopy.

Authors:  L Louis Drey; Michael C Graber; Jan Bieschke
Journal:  Biotechniques       Date:  2013-07       Impact factor: 1.993

3.  Unidirectional P-body transport during the yeast cell cycle.

Authors:  Cecilia Garmendia-Torres; Alexander Skupin; Sean A Michael; Pekka Ruusuvuori; Nathan J Kuwada; Didier Falconnet; Gregory A Cary; Carl Hansen; Paul A Wiggins; Aimée M Dudley
Journal:  PLoS One       Date:  2014-06-11       Impact factor: 3.240

4.  Automated method for the rapid and precise estimation of adherent cell culture characteristics from phase contrast microscopy images.

Authors:  Nicolas Jaccard; Lewis D Griffin; Ana Keser; Rhys J Macown; Alexandre Super; Farlan S Veraitch; Nicolas Szita
Journal:  Biotechnol Bioeng       Date:  2013-10-05       Impact factor: 4.530

5.  A Simple and Sensitive High-Content Assay for the Characterization of Antiproliferative Therapeutic Antibodies.

Authors:  Andreas Stengl; David Hörl; Heinrich Leonhardt; Jonas Helma
Journal:  SLAS Discov       Date:  2016-12-13       Impact factor: 3.341

6.  Automated noninvasive epithelial cell counting in phase contrast microscopy images with automated parameter selection.

Authors:  R Flight; G Landini; I B Styles; R M Shelton; M R Milward; P R Cooper
Journal:  J Microsc       Date:  2018-07-12       Impact factor: 1.758

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.