BACKGROUND: Recently, high-flexion PCL-retaining (CR) and -substituting (PS) knee prostheses were designed to allow greater and safer flexion after TKA. However, the advantages of high-flexion TKA over standard design have been debated in terms of early maximal flexion. A recent study reported a high incidence of early loosening of the femoral component related to the deep flexion provided by high-flexion PS TKA. QUESTIONS/PURPOSES: We determined whether high-flexion fixed bearing CR and PS prostheses would provide (1) a better flexion, (2) a better function, and (3) a higher incidence of radiographic loosening than TKA performed using standard fixed bearing CR prostheses in Asian patients. METHODS: From a total of 182 patients with primary unilateral TKA, we retrospectively reviewed 137 TKAs: 47 with high-flexion CR, 42 with high-flexion PS, and 48 with standard CR designs. ROM, Knee Society scores, and WOMAC scores were evaluated and compared among the three groups. Radiographically, we assessed radiolucent zones and component loosening. Minimum followup was 5 years (mean, 6.2 years; range, 5-8 years). RESULTS: We found no differences among the three groups in mean maximal flexion (high-flexion CR: 135°; high-flexion PS: 134°; standard CR: 136°), Knee Society scores, and WOMAC scores at last followup. Also, there were no differences among the three groups in terms of radiolucent lines around the prosthesis. No patient in any group had loosening of the femoral component. CONCLUSIONS: The high-flexion CR or PS design had no advantages over the standard CR design with respect to ROM, clinical scores, and radiolucent lines around the femoral or tibial component after 5 years' followup.
BACKGROUND: Recently, high-flexion PCL-retaining (CR) and -substituting (PS) knee prostheses were designed to allow greater and safer flexion after TKA. However, the advantages of high-flexion TKA over standard design have been debated in terms of early maximal flexion. A recent study reported a high incidence of early loosening of the femoral component related to the deep flexion provided by high-flexion PS TKA. QUESTIONS/PURPOSES: We determined whether high-flexion fixed bearing CR and PS prostheses would provide (1) a better flexion, (2) a better function, and (3) a higher incidence of radiographic loosening than TKA performed using standard fixed bearing CR prostheses in Asian patients. METHODS: From a total of 182 patients with primary unilateral TKA, we retrospectively reviewed 137 TKAs: 47 with high-flexion CR, 42 with high-flexion PS, and 48 with standard CR designs. ROM, Knee Society scores, and WOMAC scores were evaluated and compared among the three groups. Radiographically, we assessed radiolucent zones and component loosening. Minimum followup was 5 years (mean, 6.2 years; range, 5-8 years). RESULTS: We found no differences among the three groups in mean maximal flexion (high-flexion CR: 135°; high-flexion PS: 134°; standard CR: 136°), Knee Society scores, and WOMAC scores at last followup. Also, there were no differences among the three groups in terms of radiolucent lines around the prosthesis. No patient in any group had loosening of the femoral component. CONCLUSIONS: The high-flexion CR or PS design had no advantages over the standard CR design with respect to ROM, clinical scores, and radiolucent lines around the femoral or tibial component after 5 years' followup.
Authors: L Brosseau; M Tousignant; J Budd; N Chartier; L Duciaume; S Plamondon; J P O'Sullivan; S O'Donoghue; S Balmer Journal: Physiother Res Int Date: 1997
Authors: Won Chul Choi; Sahnghoon Lee; Sang Cheol Seong; Jong Hun Jung; Myung Chul Lee Journal: J Bone Joint Surg Am Date: 2010-10-15 Impact factor: 5.284
Authors: Brandon N Devers; Michael A Conditt; Miranda L Jamieson; Matthew D Driscoll; Philip C Noble; Brian S Parsley Journal: J Arthroplasty Date: 2010-04-21 Impact factor: 4.757
Authors: Juergen Götz; Johannes Beckmann; Ingo Sperrer; Clemens Baier; Silvia Dullien; Joachim Grifka; Franz Koeck Journal: Int Orthop Date: 2015-12-19 Impact factor: 3.075