Literature DB >> 23054522

No better flexion or function of high-flexion designs in Asian patients with TKA.

Jong-Keun Seon1, Ji-Hyeon Yim, Hyoung-Yeon Seo, Eun-Kyoo Song.   

Abstract

BACKGROUND: Recently, high-flexion PCL-retaining (CR) and -substituting (PS) knee prostheses were designed to allow greater and safer flexion after TKA. However, the advantages of high-flexion TKA over standard design have been debated in terms of early maximal flexion. A recent study reported a high incidence of early loosening of the femoral component related to the deep flexion provided by high-flexion PS TKA. QUESTIONS/PURPOSES: We determined whether high-flexion fixed bearing CR and PS prostheses would provide (1) a better flexion, (2) a better function, and (3) a higher incidence of radiographic loosening than TKA performed using standard fixed bearing CR prostheses in Asian patients.
METHODS: From a total of 182 patients with primary unilateral TKA, we retrospectively reviewed 137 TKAs: 47 with high-flexion CR, 42 with high-flexion PS, and 48 with standard CR designs. ROM, Knee Society scores, and WOMAC scores were evaluated and compared among the three groups. Radiographically, we assessed radiolucent zones and component loosening. Minimum followup was 5 years (mean, 6.2 years; range, 5-8 years).
RESULTS: We found no differences among the three groups in mean maximal flexion (high-flexion CR: 135°; high-flexion PS: 134°; standard CR: 136°), Knee Society scores, and WOMAC scores at last followup. Also, there were no differences among the three groups in terms of radiolucent lines around the prosthesis. No patient in any group had loosening of the femoral component.
CONCLUSIONS: The high-flexion CR or PS design had no advantages over the standard CR design with respect to ROM, clinical scores, and radiolucent lines around the femoral or tibial component after 5 years' followup.

Entities:  

Mesh:

Year:  2013        PMID: 23054522      PMCID: PMC3613541          DOI: 10.1007/s11999-012-2629-4

Source DB:  PubMed          Journal:  Clin Orthop Relat Res        ISSN: 0009-921X            Impact factor:   4.176


  30 in total

1.  Knee joint functional range of movement prior to and following total knee arthroplasty measured using flexible electrogoniometry.

Authors:  Christine M Myles; Philip J Rowe; Colin R C Walker; Richard W Nutton
Journal:  Gait Posture       Date:  2002-08       Impact factor: 2.840

2.  The early results of high-flex total knee arthroplasty: a minimum of 2 years of follow-up.

Authors:  Hsuan-Ti Huang; Jiing Yuan Su; Gwo-Jaw Wang
Journal:  J Arthroplasty       Date:  2005-08       Impact factor: 4.757

3.  Tibiofemoral contact behavior is improved in high-flexion cruciate retaining TKA.

Authors:  Ephrat Most; Peter G Sultan; Sang Eun Park; Ramprasad Papannagari; Guoan Li
Journal:  Clin Orthop Relat Res       Date:  2006-11       Impact factor: 4.176

4.  High incidence of loosening of the femoral component in legacy posterior stabilised-flex total knee replacement.

Authors:  H S Han; S-B Kang; K S Yoon
Journal:  J Bone Joint Surg Br       Date:  2007-11

Review 5.  Intratester and intertester reliability and criterion validity of the parallelogram and universal goniometers for active knee flexion in healthy subjects.

Authors:  L Brosseau; M Tousignant; J Budd; N Chartier; L Duciaume; S Plamondon; J P O'Sullivan; S O'Donoghue; S Balmer
Journal:  Physiother Res Int       Date:  1997

6.  Range of motion in total knee replacement.

Authors:  Y S Anouchi; M McShane; F Kelly; J Elting; J Stiehl
Journal:  Clin Orthop Relat Res       Date:  1996-10       Impact factor: 4.176

7.  Outcome of knee arthroplasty in patients with poor preoperative range of motion.

Authors:  James P McAuley; Michael F Harrer; Deborah Ammeen; Gerard A Engh
Journal:  Clin Orthop Relat Res       Date:  2002-11       Impact factor: 4.176

8.  Comparison between standard and high-flexion posterior-stabilized rotating-platform mobile-bearing total knee arthroplasties: a randomized controlled study.

Authors:  Won Chul Choi; Sahnghoon Lee; Sang Cheol Seong; Jong Hun Jung; Myung Chul Lee
Journal:  J Bone Joint Surg Am       Date:  2010-10-15       Impact factor: 5.284

9.  Does greater knee flexion increase patient function and satisfaction after total knee arthroplasty?

Authors:  Brandon N Devers; Michael A Conditt; Miranda L Jamieson; Matthew D Driscoll; Philip C Noble; Brian S Parsley
Journal:  J Arthroplasty       Date:  2010-04-21       Impact factor: 4.757

10.  Knee range of motion during the first two years after use of posterior cruciate-stabilizing or posterior cruciate-retaining total knee prostheses. A randomized clinical trial.

Authors:  R Chaudhary; L A Beaupré; D W C Johnston
Journal:  J Bone Joint Surg Am       Date:  2008-12       Impact factor: 5.284

View more
  3 in total

1.  Retrospective comparative study shows no significant difference in postural stability between cruciate-retaining (CR) and cruciate-substituting (PS) total knee implant systems.

Authors:  Juergen Götz; Johannes Beckmann; Ingo Sperrer; Clemens Baier; Silvia Dullien; Joachim Grifka; Franz Koeck
Journal:  Int Orthop       Date:  2015-12-19       Impact factor: 3.075

2.  Active Flexion in Weight Bearing Better Correlates with Functional Outcomes of Total Knee Arthroplasty than Passive Flexion.

Authors:  Young Dong Song; Nimash Jain; Yeon Gwi Kang; Tae Yune Kim; Tae Kyun Kim
Journal:  Knee Surg Relat Res       Date:  2016-06-01

3.  Is Achieving High Flexion Necessary for Satisfaction after Total Knee Arthroplasty in Indian Patients?

Authors:  Ashutosh Purushottam Mavalankar; Shubha Rani
Journal:  Indian J Orthop       Date:  2019 Mar-Apr       Impact factor: 1.251

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.