BACKGROUND: Aim of this study is the presentation of long-term results regarding the effectiveness and safety of the implantation of Ahmed glaucoma valve (AGV) devices using a pars plana approach after vitrectomy in the treatment of therapy refractive glaucoma. METHODS: The implantation of AGV devices using a pars plana approach after vitrectomy was performed in 27 eyes of 22 patients with neovascular glaucoma (n = 7 patients), uveitis (n = 6), complex juvenile secondary glaucoma (n = 4), primary open angle glaucoma (n = 3), pseudoexfoliation glaucoma (n = 1) and nanophthalmus (n = 1). Intraocular pressure, visual acuity and subsequent complications were documented. The mean follow-up period was 23.6 months. RESULTS: Intraocular pressure was significantly reduced from 30.2 mmHg preoperatively to 13 mmHg after a follow-up of 36 months. The mean visual acuity did not change significantly, five eyes required a subsequent explantation of which three were due to AGV-related complications. CONCLUSIONS: The implantation of AGV devices using a pars plana approach permits an effective and permanent reduction of intraocular pressure (IOP) even in severe therapy refractive secondary glaucoma; however, the risk of serious sight-threatening complications has to be taken into account.
BACKGROUND: Aim of this study is the presentation of long-term results regarding the effectiveness and safety of the implantation of Ahmed glaucoma valve (AGV) devices using a pars plana approach after vitrectomy in the treatment of therapy refractive glaucoma. METHODS: The implantation of AGV devices using a pars plana approach after vitrectomy was performed in 27 eyes of 22 patients with neovascular glaucoma (n = 7 patients), uveitis (n = 6), complex juvenile secondary glaucoma (n = 4), primary open angle glaucoma (n = 3), pseudoexfoliation glaucoma (n = 1) and nanophthalmus (n = 1). Intraocular pressure, visual acuity and subsequent complications were documented. The mean follow-up period was 23.6 months. RESULTS: Intraocular pressure was significantly reduced from 30.2 mmHg preoperatively to 13 mmHg after a follow-up of 36 months. The mean visual acuity did not change significantly, five eyes required a subsequent explantation of which three were due to AGV-related complications. CONCLUSIONS: The implantation of AGV devices using a pars plana approach permits an effective and permanent reduction of intraocular pressure (IOP) even in severe therapy refractive secondary glaucoma; however, the risk of serious sight-threatening complications has to be taken into account.
Authors: Panos G Christakis; Jeffrey W Kalenak; David Zurakowski; James C Tsai; Jeffrey A Kammer; Paul J Harasymowycz; Iqbal I K Ahmed Journal: Ophthalmology Date: 2011-09-01 Impact factor: 12.079
Authors: Donald L Budenz; Keith Barton; William J Feuer; Joyce Schiffman; Vital P Costa; David G Godfrey; Yvonne M Buys Journal: Ophthalmology Date: 2010-10-08 Impact factor: 12.079
Authors: R S Ayyala; D Zurakowski; J A Smith; R Monshizadeh; P A Netland; D W Richards; W E Layden Journal: Ophthalmology Date: 1998-10 Impact factor: 12.079