Literature DB >> 23051888

Diagnostic accuracy of cardiac positron emission tomography versus single photon emission computed tomography for coronary artery disease: a bivariate meta-analysis.

Matthew W Parker1, Aline Iskandar, Brendan Limone, Andrew Perugini, Hyejin Kim, Charles Jones, Brian Calamari, Craig I Coleman, Gary V Heller.   

Abstract

BACKGROUND: Positron emission tomography (PET) myocardial perfusion imaging (MPI) offers technical benefits compared with single photon emission computed tomography (SPECT) MPI, but there has been no systematic comparison of their diagnostic accuracy for coronary artery disease. We performed a bivariate meta-analysis of the published literature to compare the sensitivity and specificity of PET versus SPECT stress MPI for ≥50% stenosis of any epicardial coronary artery in patients with known or suspected coronary artery disease. METHODS AND
RESULTS: We searched MEDLINE and EMBASE from inception through January 2012 and the references of identified studies for prospective, English language studies that evaluated the sensitivity and specificity of PET and/or SPECT MPI with coronary angiography as the reference standard and reported sufficient data to calculate patient-level true and false positives and negatives. Two investigators independently extracted patient and study characteristics; a third investigator resolved any disagreements. We identified 117 studies, including 108 evaluating SPECT MPI, 4 evaluating PET MPI, and 5 evaluating both modalities. Bivariate meta-analysis demonstrated a significantly higher pooled mean sensitivity with PET (92.6% [95% Confidence Interval, 88.3% to 95.5%]) compared with SPECT (88.3% [95% confidence interval, 86.4% to 90.0%]) (P=0.035). No significant difference in specificity was observed between PET (81.3% [95% confidence interval, 66.6% to 90.4%]) and SPECT (75.8% [95% confidence interval, 72.1% to 79.1%]) (P=0.39). Few studies investigated coronary angiography with PET. Only 5 studies directly compared SPECT and PET.
CONCLUSIONS: In a meta-analysis of 11,862 patients, PET MPI demonstrated a higher sensitivity for coronary artery disease than SPECT MPI. No difference in specificity was detected in the pooled analysis of PET and SPECT MPI.

Entities:  

Mesh:

Year:  2012        PMID: 23051888     DOI: 10.1161/CIRCIMAGING.112.978270

Source DB:  PubMed          Journal:  Circ Cardiovasc Imaging        ISSN: 1941-9651            Impact factor:   7.792


  63 in total

1.  A combined static-dynamic single-dose imaging protocol to compare quantitative dynamic SPECT with static conventional SPECT.

Authors:  Maria Sciammarella; Uttam M Shrestha; Youngho Seo; Grant T Gullberg; Elias H Botvinick
Journal:  J Nucl Cardiol       Date:  2017-08-03       Impact factor: 5.952

2.  Ischaemic vs non-ischaemic dilated cardiomyopathy: The value of nuclear cardiology techniques.

Authors:  Federico Caobelli; Frank M Bengel
Journal:  J Nucl Cardiol       Date:  2015-07-08       Impact factor: 5.952

Review 3.  Relationship between Calcium Score and Myocardial Scintigraphy in the Diagnosis of Coronary Disease.

Authors:  Fabio Paiva Rossini Siqueira; Claudio Tinoco Mesquita; Alair Augusto Sarmet M Damas Dos Santos; Marcelo Souto Nacif
Journal:  Arq Bras Cardiol       Date:  2016-07-18       Impact factor: 2.000

4.  Nuclear cardiology in the present and beyond: can we meet the challenges?

Authors:  Gary V Heller
Journal:  J Nucl Cardiol       Date:  2013-05-25       Impact factor: 5.952

Review 5.  PET/MRI: current state of the art and future potential for cardiovascular applications.

Authors:  Nebiyu Adenaw; Michael Salerno
Journal:  J Nucl Cardiol       Date:  2013-12       Impact factor: 5.952

6.  High-risk coronary artery disease, but normal myocardial perfusion: A matter of concern?

Authors:  Shu Yokota; Mohamed Mouden; Jan Paul Ottervanger
Journal:  J Nucl Cardiol       Date:  2015-05-21       Impact factor: 5.952

Review 7.  Proceedings of the ASNC Cardiac PET Summit, 12 May 2014, Baltimore, MD : 1: The value of PET: Integrating cardiovascular PET into the care continuum.

Authors:  Rob Beanlands; Gary V Heller
Journal:  J Nucl Cardiol       Date:  2015-04-24       Impact factor: 5.952

8.  Influence of cardiac stress protocol on myocardial perfusion imaging accuracy: The role of exercise level on the evaluation of ischemic burden.

Authors:  Alessia Gimelli; Riccardo Liga; Emilio Maria Pasanisi; Mirta Casagranda; Michele Coceani; Paolo Marzullo
Journal:  J Nucl Cardiol       Date:  2015-03-27       Impact factor: 5.952

Review 9.  Machine learning in quantitative PET: A review of attenuation correction and low-count image reconstruction methods.

Authors:  Tonghe Wang; Yang Lei; Yabo Fu; Walter J Curran; Tian Liu; Jonathon A Nye; Xiaofeng Yang
Journal:  Phys Med       Date:  2020-07-29       Impact factor: 2.685

10.  Implementation of a cardiac PET stress program: comparison of outcomes to the preceding SPECT era.

Authors:  Stacey Knight; David B Min; Viet T Le; Kent G Meredith; Ritesh Dhar; Santanu Biswas; Kurt R Jensen; Steven M Mason; Jon-David Ethington; Donald L Lappe; Joseph B Muhlestein; Jeffrey L Anderson; Kirk U Knowlton
Journal:  JCI Insight       Date:  2018-05-03
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.