Literature DB >> 23048051

Comparison of resolute zotarolimus-eluting stents and sirolimus-eluting stents in patients with de novo long coronary artery lesions: a randomized LONG-DES IV trial.

Jung-Min Ahn1, Duk-Woo Park, Young-Hak Kim, Haegeun Song, Young-Rak Cho, Won-Jang Kim, Jong-Young Lee, Soo-Jin Kang, Seung-Whan Lee, Cheol Whan Lee, Seong-Wook Park, Sung-Cheol Yun, Seungbong Han, Sung Yun Lee, Bong-Ki Lee, Jang-Hyun Cho, Tae-Hyun Yang, Nae-Hee Lee, Joo-Young Yang, Jong-Seon Park, Won-Yong Shin, Moo Hyun Kim, Jang Ho Bae, Myeong-Kon Kim, Junghan Yoon, Seung-Jung Park.   

Abstract

BACKGROUND: Procedural and clinical outcomes still remain unfavorable for patients with long coronary lesions who undergo stent-based coronary interventions. Therefore, we compared the relative efficacy and safety of resolute zotarolimus-eluting stents (R-ZES) and sirolimus-eluting stents (SES) for patients with de novo long coronary lesions. METHODS AND
RESULTS: This randomized, multicenter, prospective trial, called the Percutaneous Treatment of LONG Native Coronary Lesions With Drug-Eluting Stent-IV (LONG-DES IV) trial, compared long R-ZES and SES in 500 patients with long (≥25 mm) native coronary lesions. The primary end point of the trial was in-segment late luminal loss at 9-month angiographic follow-up. The baseline characteristics were not different between R-ZES and SES groups, including lesion lengths (32.4±13.5 mm versus 31.0±13.5 mm, P=0.27). At 9-month angiographic follow-up, the R-ZES was noninferior to the SES with respect to in-segment late luminal loss, the primary study end point (0.14±0.38 mm versus 0.12±0.43 mm, P for noninferiority=0.03, P for superiority=0.68). In addition, in-stent late luminal loss (0.26±0.36 mm versus 0.24±0.42 mm, P=0.78) and the rates of in-segment (5.2% versus 7.2%, P=0.44) and in-stent (4.0% versus 6.0%, P=0.41) binary restenosis were not significantly different between the 2 groups. There were no significant between-group differences in the rate of adverse clinical events (death, myocardial infarction, stent thrombosis, target-lesion revascularization, and composite outcomes).
CONCLUSIONS: For patients with de novo long coronary artery disease, R-ZES implantation showed noninferior angiographic outcomes as compared with SES implantation. CLINICAL TRIAL REGISTRATION: URL: http://www.clinicaltrials.gov. Unique identifier: NCT01186094.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 23048051     DOI: 10.1161/CIRCINTERVENTIONS.111.965673

Source DB:  PubMed          Journal:  Circ Cardiovasc Interv        ISSN: 1941-7640            Impact factor:   6.546


  6 in total

Review 1.  New concepts in the design of drug-eluting coronary stents.

Authors:  Scot Garg; Christos Bourantas; Patrick W Serruys
Journal:  Nat Rev Cardiol       Date:  2013-02-19       Impact factor: 32.419

2.  Prospective study to evaluate safety and efficacy of Zotarolimus Eluting Stent (PSEZES) in patients with long coronary artery lesions.

Authors:  C G Bahuleyan; V V Krishna Kumar; Shifas Babu
Journal:  Indian Heart J       Date:  2015-05-13

3.  Percutaneous coronary intervention using a full metal jacket with drug-eluting stents: major adverse cardiac events at one year.

Authors:  Rita Calé; Rui Campante Teles; Manuel Almeida; Ingrid do Rosário; Pedro Jerónimo Sousa; João Brito; Luís Raposo; Pedro de Araújo Gonçalves; Henrique Mesquita Gabriel; Miguel Mendes
Journal:  Arq Bras Cardiol       Date:  2013-07-02       Impact factor: 2.000

4.  First-generation versus second-generation drug-eluting stents in current clinical practice: updated evidence from a comprehensive meta-analysis of randomised clinical trials comprising 31 379 patients.

Authors:  Eliano Pio Navarese; Mariusz Kowalewski; David Kandzari; Alexandra Lansky; Bartosz Górny; Lukasz Kołtowski; Ron Waksman; Sergio Berti; Giuseppe Musumeci; Ugo Limbruno; Rene J van der Schaaf; Malte Kelm; Jacek Kubica; Harry Suryapranata
Journal:  Open Heart       Date:  2014-08-21

5.  Clinical Outcomes from Unselected "Real-World" Patients with Long Coronary Lesion Receiving 40 mm Biodegradable Polymer Coated Sirolimus-Eluting Stent.

Authors:  Anurag Polavarapu; Raghava Sarma Polavarapu; Jayesh Prajapati; Kamlesh Thakkar; Asif Raheem; Tamanpreet Mayall; Ashok Thakkar
Journal:  Scientifica (Cairo)       Date:  2015-10-22

6.  Safety and efficacy outcomes of first and second generation durable polymer drug eluting stents and biodegradable polymer biolimus eluting stents in clinical practice: comprehensive network meta-analysis.

Authors:  Eliano P Navarese; Kenneth Tandjung; Bimmer Claessen; Felicita Andreotti; Mariusz Kowalewski; David E Kandzari; Dean J Kereiakes; Ron Waksman; Laura Mauri; Ian T Meredith; Aloke V Finn; Hyo-Soo Kim; Jacek Kubica; Harry Suryapranata; Toni Mustahsani Aprami; Giuseppe Di Pasquale; Clemens von Birgelen; Elvin Kedhi
Journal:  BMJ       Date:  2013-11-06