Literature DB >> 23044772

Determination of nitrate and nitrite in freshwaters using flow-injection with luminol chemiluminescence detection.

Mohammad Yaqoob1, Beatriz Folgado Biot, Abdul Nabi, Paul J Worsfold.   

Abstract

A simple and sensitive flow-injection (FI) method for the determination of nitrate and nitrite in natural waters, based on luminol chemiluminescence (CL) detection, is reported. Nitrate was reduced online to nitrite via a copperized cadmium (Cu-Cd) column and then reacted with acidic hydrogen peroxide to form peroxynitrous acid. CL emission was observed from the oxidation of luminol in an alkaline medium in the presence of the peroxynitrite anion. The limits of detection (S:N = 3) were 0.02 and 0.01 µg N/L, with sample throughputs of 40 and 90 /h for nitrate and nitrite, respectively. Calibration graphs were linear over the range 0.02-50 and 0.01-50 µg N/L [R2  = 0.9984 (n = 8) and R2  = 0.9965 (n = 7)] for nitrate and nitrite, respectively, with relative standard deviations (RSDs; n = 3) in the range 1.8-4.6%. The key chemical and physical variables (reagent concentrations, buffer pH, flow rates, sample volume, Cu-Cd reductor column length) were optimized and potential interferences investigated. The effect of cations [Ca(II), Mg(II), Co(II), Fe(II) and Cu(II)] was masked online with EDTA. Common anions (PO4(3-) , SO4(2-) and HCO3-) did not interfere at their maximum admissible concentrations in freshwaters. The effect of salinity on the luminol CL reaction with and without nitrate and nitrite (2 and 0.5 µg N/L, respectively) was also investigated. The method was successfully applied to freshwaters and the results obtained were in good agreement with those obtained by an automated segmented flow analyser reference method.
Copyright © 2011 John Wiley & Sons, Ltd.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 23044772     DOI: 10.1002/bio.1366

Source DB:  PubMed          Journal:  Luminescence        ISSN: 1522-7235            Impact factor:   2.464


  3 in total

Review 1.  Luminol-based chemiluminescent signals: clinical and non-clinical application and future uses.

Authors:  Parvez Khan; Danish Idrees; Michael A Moxley; John A Corbett; Faizan Ahmad; Guido von Figura; William S Sly; Abdul Waheed; Md Imtaiyaz Hassan
Journal:  Appl Biochem Biotechnol       Date:  2014-04-22       Impact factor: 2.926

Review 2.  Autonomous and In Situ Ocean Environmental Monitoring on Optofluidic Platform.

Authors:  Fang Wang; Jiaomeng Zhu; Longfei Chen; Yunfeng Zuo; Xuejia Hu; Yi Yang
Journal:  Micromachines (Basel)       Date:  2020-01-08       Impact factor: 2.891

3.  Construction of a Ginseng Root-Meristem Sensor and a Sensing Kinetics Study on the Main Nitrogen Nutrients.

Authors:  Shiang Wang; Dingqiang Lu; Guangchang Pang
Journal:  Sensors (Basel)       Date:  2021-01-20       Impact factor: 3.576

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.