Effect of ultrasound on adherent microbubble contrast agents.

Jonathan Loughran1, Charles Sennoga, Robert J Eckersley, Meng-Xing Tang.   

Abstract

An investigation into the effect of clinical ultrasound exposure on adherent microbubbles is described. A flow phantom was constructed in which targeted microbubbles were attached using biotin-streptavidin linkages. Microbubbles were insonated by broadband imaging pulses (centred at 2.25 MHz) over a range of pressures (peak negative pressure (PNP) = 60-375 kPa). Individual adherent bubbles were observed optically and classified as either being isolated or with a single neighbouring bubble. It is found that bubble detachment and deflation are two significant effects, even during low amplitude ultrasound exposure. Specifically, while at very low acoustic pressure (PNP < 75 kPa) 95% of the bubbles were not affected, at medium pressure (151 kPa < P < 225 kPa) 53% of the bubbles detached and at higher pressures (301 kPa < P < 375 kPa) 96% of the bubbles detached. In addition, more than 50% of the bubbles underwent deflation at pressures between 301 and 375 kPa. At pressures between 226 and 300 kPa, more adherent bubbles detached when there was a neighbouring bubble, suggesting the role of multiple scattering and secondary Bjerknes force on bubble detachment. The flow shear, primary and secondary Bjerknes forces exerted on each bubble were calculated and compared to the estimated forces acting on the bubble due to oscillations. The oscillation force is shown to be much higher than other forces. The mechanisms of bubble detachment are discussed.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 23044731     DOI: 10.1088/0031-9155/57/21/6999

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  3 in total

1.  The Use of Acoustic Radiation Force Decorrelation-Weighted Pulse Inversion for Enhanced Ultrasound Contrast Imaging.

Authors:  Elizabeth B Herbst; Sunil Unnikrishnan; Shiying Wang; Alexander L Klibanov; John A Hossack; Frank William Mauldin
Journal:  Invest Radiol       Date:  2017-02       Impact factor: 6.016

2.  Shear forces from flow are responsible for a distinct statistical signature of adherent microbubbles in large vessels.

Authors:  Shiying Wang; F William Mauldin; Alexander L Klibanov; John A Hossack
Journal:  Mol Imaging       Date:  2013-09       Impact factor: 4.488

3.  Molecular Acoustic Angiography: A New Technique for High-resolution Superharmonic Ultrasound Molecular Imaging.

Authors:  Sarah E Shelton; Brooks D Lindsey; James K Tsuruta; F Stuart Foster; Paul A Dayton
Journal:  Ultrasound Med Biol       Date:  2015-12-08       Impact factor: 2.998

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.