Literature DB >> 23043763

Implementation of a dose-response curve for γ-radiation in the Portuguese population by use of the chromosomal aberration assay.

V Martins1, A C Antunes, O Monteiro Gil.   

Abstract

An in vitro dose-response curve following exposure to γ-radiation was determined at the IST/ITN, by use of the chromosomal aberration assay. This is the first study of this kind carried out among the Portuguese population. Un-irradiated and γ-irradiated peripheral blood lymphocytes from 16 healthy donors were cultured. A total of 22,395 metaphases were analyzed for frequency and distribution of dicentrics and centric rings, as a function of the radiation dose. The dose-response data for dicentrics and dicentrics plus centric rings were fitted by use of a linear-quadratic model: Y(dic)=(0.0011±0.0006)+(0.0105±0.0035)D+(0.0480±0.0019)D(2) and Y(dic+rings)=(0.0011±0.0006)+(0.0095±0.0036)D+(0.0536±0.0020)D(2). Also, calibration curves related to age and gender were determined, but no significant differences were found. Following the establishment of the dose-response curves, a validation experiment was carried out with three individuals. Real and estimated doses, obtained with the dose-response curves, were in agreement. These results give us confidence to apply both dose-response calibration curves in future biological dosimetry requirements.
Copyright © 2012 Elsevier B.V. All rights reserved.

Mesh:

Year:  2012        PMID: 23043763     DOI: 10.1016/j.mrgentox.2012.09.009

Source DB:  PubMed          Journal:  Mutat Res        ISSN: 0027-5107            Impact factor:   2.433


  5 in total

Review 1.  Radiation signature on exposed cells: Relevance in dose estimation.

Authors:  Venkatachalam Perumal; Tamizh Selvan Gnana Sekaran; Venkateswarlu Raavi; Safa Abdul Syed Basheerudeen; Karthik Kanagaraj; Amith Roy Chowdhury; Solomon Fd Paul
Journal:  World J Radiol       Date:  2015-09-28

2.  Establishing cytogenetic biodosimetry laboratory in Saudi Arabia and producing preliminary calibration curve of dicentric chromosomes as biomarker for medical dose estimation in response to radiation emergencies.

Authors:  Khaled Al-Hadyan; Sara Elewisy; Belal Moftah; Mohamed Shoukri; Awad Alzahrany; Ghazi Alsbeih
Journal:  3 Biotech       Date:  2014-04-18       Impact factor: 2.406

3.  Development of Dose-Response Calibration Curve for Dicentric Chromosome Induced by X-Rays.

Authors:  Yanti Lusiyanti; Mukh Syaifudin; Tuti Budiantari; Sofiati Purnami; Dwi Ramadhani
Journal:  Genome Integr       Date:  2019-07-19

4.  Calibration curves by 60Co with low dose rate are different in terms of dose estimation - a comparative study.

Authors:  Mariana Esposito Mendes; Julyanne Conceição Goes de Mendonça; Suy Hwang; Marina Di Giorgio; Fabiana Farias de Lima; Neide Santos
Journal:  Genet Mol Biol       Date:  2020-02-17       Impact factor: 1.771

5.  A dose-response curve for biodosimetry from a 6 MV electron linear accelerator.

Authors:  M M P Lemos-Pinto; M Cadena; N Santos; T S Fernandes; E Borges; A Amaral
Journal:  Braz J Med Biol Res       Date:  2015-05-26       Impact factor: 2.590

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.