Numerical simulations of eye globes often rely on topographies that have been measured in vivo using devices such as the Pentacam or OCT. The topographies, which represent the form of the already stressed eye under the existing intraocular pressure, introduce approximations in the analysis. The accuracy of the simulations could be improved if either the stress state of the eye under the effect of intraocular pressure is determined, or the stress-free form of the eye estimated prior to conducting the analysis. This study reviews earlier attempts to address this problem and assesses the performance of an iterative technique proposed by Pandolfi and Holzapfel [1], which is both simple to implement and promises high accuracy in estimating the eye's stress-free form. A parametric study has been conducted and demonstrated reliance of the error level on the level of flexibility of the eye model, especially in the cornea region. However, in all cases considered 3-4 analysis iterations were sufficient to produce a stress-free form with average errors in node location <10(-6)mm and a maximal error <10(-4)mm. This error level, which is similar to what has been achieved with other methods and orders of magnitude lower than the accuracy of current clinical topography systems, justifies the use of the technique as a pre-processing step in ocular numerical simulations. Crown
Copyright © 2012. Published by Elsevier Ltd. All rights reserved.

Entities:  

Mesh:

Year:  2012        PMID: 23041490     DOI: 10.1016/j.medengphy.2012.09.006

Source DB:  PubMed          Journal:  Med Eng Phys        ISSN: 1350-4533            Impact factor:   2.242


  13 in total

1.  A Large-Scale Computational Analysis of Corneal Structural Response and Ectasia Risk in Myopic Laser Refractive Surgery.

Authors:  William Joseph Dupps; Ibrahim Seven
Journal:  Trans Am Ophthalmol Soc       Date:  2016-08

2.  Patterned corneal collagen crosslinking for astigmatism: computational modeling study.

Authors:  Ibrahim Seven; Abhijit Sinha Roy; William J Dupps
Journal:  J Cataract Refract Surg       Date:  2014-04-24       Impact factor: 3.351

3.  Contralateral Eye Comparison of SMILE and Flap-Based Corneal Refractive Surgery: Computational Analysis of Biomechanical Impact.

Authors:  Ibrahim Seven; Ali Vahdati; Iben Bach Pedersen; Anders Vestergaard; Jesper Hjortdal; Cynthia J Roberts; William J Dupps
Journal:  J Refract Surg       Date:  2017-07-01       Impact factor: 3.573

4.  Sensitivity of corneal biomechanical and optical behavior to material parameters using design of experiments method.

Authors:  Mengchen Xu; Amy L Lerner; Paul D Funkenbusch; Ashutosh Richhariya; Geunyoung Yoon
Journal:  Comput Methods Biomech Biomed Engin       Date:  2018-02       Impact factor: 1.763

5.  Coupled biomechanical response of the cornea assessed by non-contact tonometry. A simulation study.

Authors:  Miguel Á Ariza-Gracia; Jesús F Zurita; David P Piñero; José F Rodriguez-Matas; Begoña Calvo
Journal:  PLoS One       Date:  2015-03-17       Impact factor: 3.240

6.  Comparison of Patient-Specific Computational Modeling Predictions and Clinical Outcomes of LASIK for Myopia.

Authors:  Ibrahim Seven; Ali Vahdati; Vinicius Silbiger De Stefano; Ronald R Krueger; William J Dupps
Journal:  Invest Ophthalmol Vis Sci       Date:  2016-11-01       Impact factor: 4.799

7.  Optimal Contrast Agent Staining of Ligaments and Tendons for X-Ray Computed Tomography.

Authors:  Richard Balint; Tristan Lowe; Tom Shearer
Journal:  PLoS One       Date:  2016-04-14       Impact factor: 3.240

8.  Biomechanical Impact of the Sclera on Corneal Deformation Response to an Air-Puff: A Finite-Element Study.

Authors:  B Audrey Nguyen; Cynthia J Roberts; Matthew A Reilly
Journal:  Front Bioeng Biotechnol       Date:  2019-01-10

9.  Simulation of Air Puff Tonometry Test Using Arbitrary Lagrangian-Eulerian (ALE) Deforming Mesh for Corneal Material Characterisation.

Authors:  Osama Maklad; Ashkan Eliasy; Kai-Jung Chen; Vassilios Theofilis; Ahmed Elsheikh
Journal:  Int J Environ Res Public Health       Date:  2019-12-19       Impact factor: 3.390

10.  Optical Coherence Elastography-Based Corneal Strain Imaging During Low-Amplitude Intraocular Pressure Modulation.

Authors:  Sabine Kling; Hossein Khodadadi; Orcun Goksel
Journal:  Front Bioeng Biotechnol       Date:  2020-01-31
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.