Literature DB >> 23038413

Electrospun fibre diameter, not alignment, affects mesenchymal stem cell differentiation into the tendon/ligament lineage.

Robyn D Cardwell1, Linda A Dahlgren, Aaron S Goldstein.   

Abstract

Efforts to develop engineered tendons and ligaments have focused on the use of a biomaterial scaffold and a stem cell source. However, the ideal scaffold microenvironment to promote stem cell differentiation and development of organized extracellular matrix is unknown. Through electrospinning, fibre scaffolds can be designed with tailorable architectures to mimic the intended tissue. In this study, the effects of fibre diameter and orientation were examined by electrospinning thin mats, consisting of small (< 1 µm), medium (1-2 µm) or large (> 2 µm) diameter fibres with either random or aligned fibre orientation. C3H10T1/2 model stem cells were cultured on the six different electrospun mats, as well as smooth spin-coated films, and the morphology, growth and expression of tendon/ligament genes were evaluated. The results demonstrated that fibre diameter affects cellular behaviour more significantly than fibre alignment. Initially, cell density was greater on the small fibre diameter mats, but similar cell densities were found on all mats after an additional week in culture. After 2 weeks, gene expression of collagen 1α1 and decorin was increased on all mats compared to films. Expression of the tendon/ligament transcription factor scleraxis was suppressed on all electrospun mats relative to spin-coated films, but expression on the large-diameter fibre mats was consistently greater than on the medium-diameter fibre mats. These results suggest that larger-diameter fibres (e.g. > 2 µm) may be more suitable for in vitro development of a tendon/ligament tissue.
Copyright © 2012 John Wiley & Sons, Ltd.

Entities:  

Keywords:  decorin; electrospinning; ligament; poly(esterurethane urea); scleraxis

Mesh:

Substances:

Year:  2012        PMID: 23038413     DOI: 10.1002/term.1589

Source DB:  PubMed          Journal:  J Tissue Eng Regen Med        ISSN: 1932-6254            Impact factor:   3.963


  37 in total

1.  Polymeric 3D Printed Structures for Soft-Tissue Engineering.

Authors:  Scott Stratton; Ohan S Manoukian; Ravi Patel; Adam Wentworth; Swetha Rudraiah; Sangamesh G Kumbar
Journal:  J Appl Polym Sci       Date:  2017-09-14       Impact factor: 3.125

2.  Static and cyclic mechanical loading of mesenchymal stem cells on elastomeric, electrospun polyurethane meshes.

Authors:  Robyn D Cardwell; Jonathan A Kluge; Patrick S Thayer; Scott A Guelcher; Linda A Dahlgren; David L Kaplan; Aaron S Goldstein
Journal:  J Biomech Eng       Date:  2015-06-03       Impact factor: 2.097

Review 3.  Regeneration of the anterior cruciate ligament: Current strategies in tissue engineering.

Authors:  Thomas Nau; Andreas Teuschl
Journal:  World J Orthop       Date:  2015-01-18

4.  Braided and Stacked Electrospun Nanofibrous Scaffolds for Tendon and Ligament Tissue Engineering.

Authors:  Benjamin B Rothrauff; Brian B Lauro; Guang Yang; Richard E Debski; Volker Musahl; Rocky S Tuan
Journal:  Tissue Eng Part A       Date:  2017-02-10       Impact factor: 3.845

5.  Multilayered electrospun scaffolds for tendon tissue engineering.

Authors:  Abby Chainani; Kirk J Hippensteel; Alysha Kishan; N William Garrigues; David S Ruch; Farshid Guilak; Dianne Little
Journal:  Tissue Eng Part A       Date:  2013-08-29       Impact factor: 3.845

Review 6.  Mesenchymal stem cell cultivation in electrospun scaffolds: mechanistic modeling for tissue engineering.

Authors:  Ágata Paim; Isabel C Tessaro; Nilo S M Cardozo; Patricia Pranke
Journal:  J Biol Phys       Date:  2018-03-05       Impact factor: 1.365

7.  In vitro characterization of a novel tissue engineered based hybridized nano and micro structured collagen implant and its in vivo role on tenoinduction, tenoconduction, tenogenesis and tenointegration.

Authors:  Ahmad Oryan; Ali Moshiri; Abdolhamid Meimandi-Parizi
Journal:  J Mater Sci Mater Med       Date:  2013-12-11       Impact factor: 3.896

Review 8.  In Vitro Innovation of Tendon Tissue Engineering Strategies.

Authors:  Maria Rita Citeroni; Maria Camilla Ciardulli; Valentina Russo; Giovanna Della Porta; Annunziata Mauro; Mohammad El Khatib; Miriam Di Mattia; Devis Galesso; Carlo Barbera; Nicholas R Forsyth; Nicola Maffulli; Barbara Barboni
Journal:  Int J Mol Sci       Date:  2020-09-14       Impact factor: 5.923

9.  Electrospun thymosin Beta-4 loaded PLGA/PLA nanofiber/ microfiber hybrid yarns for tendon tissue engineering application.

Authors:  Shaohua Wu; Rong Zhou; Fang Zhou; Philipp N Streubel; Shaojuan Chen; Bin Duan
Journal:  Mater Sci Eng C Mater Biol Appl       Date:  2019-10-12       Impact factor: 7.328

10.  Transient Scleraxis Overexpression Combined with Cyclic Strain Enhances Ligament Cell Differentiation.

Authors:  Anne E C Nichols; Stephen R Werre; Linda A Dahlgren
Journal:  Tissue Eng Part A       Date:  2018-05-10       Impact factor: 3.845

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.