Visualization of ovarian tumors using 3T MR imaging: diagnostic effectiveness and difficulties.

Tomoko Uehara1, Junko Takahama, Nagaaki Marugami, Aki Takahashi, Megumi Takewa, Takahiro Itoh, Satoru Kitano, Hiroyuki Nakagawa, Kimihiko Kichikawa.   

Abstract

PURPOSE: We evaluated the diagnostic effectiveness of magnetic resonance (MR) imaging at 3 tesla to visualize ovarian tumors and problems associated with its use.
MATERIALS AND METHODS: From the records of 423 consecutive women who underwent pelvic MR imaging using a 3T system from April 2009 to June 2010, we analyzed 50 continuous cases of ovarian tumors proved by histopathology. We evaluated visualization of these tumors for image quality and artifacts using 5-point scales. For qualitative assessment, we scored overall image quality (1, poor, to 5, excellent), degree of conviction regarding the diagnosis (1, undiagnosable, to 5, diagnosable with high certainty), and 4 representative artifacts (penetrating, chemical shift, motion, and susceptibility artifact) (1, severe, to 5, little degradation). We also retrospectively reviewed the diagnostic features of the ovarian tumors and preoperative diagnostic accuracy. For quantitative assessment, we determined tumor size and ADC value.
RESULTS: Overall quality score was scored 4.9±0.5, and conviction regarding diagnosis was 4.9±0.3. Artifacts caused little degradation in most cases: penetrating, 4.8±0.5; chemical shift, 4.3±0.5; motion, 4.6±0.6; and susceptibility, 3.8±0.9. Preoperative diagnostic accuracy was 92% (sensitivity 94.7%, specificity 90.3%). Mean tumor diameter was 88.3±61 mm. The mean ADC value was 1.04±0.3 in malignant tumors and 1.15±0.5 (×10⁻⁶ mm²/s) in benign tumors.
CONCLUSION: The quality of ovarian tumor images obtained with a 3T MR imaging system is adequate for diagnosis, with only slight degradation from penetrating or susceptibility artifacts.

Entities:  

Mesh:

Year:  2012        PMID: 23037561     DOI: 10.2463/mrms.11.171

Source DB:  PubMed          Journal:  Magn Reson Med Sci        ISSN: 1347-3182            Impact factor:   2.471


  3 in total

1.  Estimation of optimal b-value sets for obtaining apparent diffusion coefficient free from perfusion in non-small cell lung cancer.

Authors:  Kishor Karki; Geoffrey D Hugo; John C Ford; Kathryn M Olsen; Siddharth Saraiya; Robert Groves; Elisabeth Weiss
Journal:  Phys Med Biol       Date:  2015-09-25       Impact factor: 3.609

2.  MR findings of primary ovarian granulosa cell tumor with focus on the differentiation with other ovarian sex cord-stromal tumors.

Authors:  He Zhang; Hongyu Zhang; Shouxin Gu; Yanyu Zhang; Xuefen Liu; Guofu Zhang
Journal:  J Ovarian Res       Date:  2018-06-05       Impact factor: 4.234

3.  A new phantom and empirical formula for apparent diffusion coefficient measurement by a 3 Tesla magnetic resonance imaging scanner.

Authors:  Marina Hara; Masahiro Kuroda; Yuichi Ohmura; Hidenobu Matsuzaki; Tomoki Kobayashi; Jun Murakami; Kazunori Katashima; Masakazu Ashida; Seiichiro Ohno; Jun-Ichi Asaumi
Journal:  Oncol Lett       Date:  2014-05-28       Impact factor: 2.967

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.