Literature DB >> 23037046

Improved signal model for confocal sensors accounting for object depending artifacts.

Florian Mauch1, Wolfram Lyda, Marc Gronle, Wolfgang Osten.   

Abstract

The conventional signal model of confocal sensors is well established and has proven to be exceptionally robust especially when measuring rough surfaces. Its physical derivation however is explicitly based on plane surfaces or point like objects, respectively. Here we show experimental results of a confocal point sensor measurement of a surface standard. The results illustrate the rise of severe artifacts when measuring curved surfaces. On this basis, we present a systematic extension of the conventional signal model that is proven to be capable of qualitatively explaining these artifacts.

Mesh:

Year:  2012        PMID: 23037046     DOI: 10.1364/OE.20.019936

Source DB:  PubMed          Journal:  Opt Express        ISSN: 1094-4087            Impact factor:   3.894


  1 in total

1.  Multi-view object topography measurement with optical sectioning structured illumination microscopy.

Authors:  Feifei Ren; Zhaojun Wang; Jia Qian; Yansheng Liang; Shipei Dang; Yanan Cai; Piero R Bianco; Baoli Yao; Ming Lei
Journal:  Appl Opt       Date:  2019-08-10       Impact factor: 1.905

  1 in total