Influence of formalin fixation on the implant stability quotient and mechanical characteristics of bone.

Koji Morita1, Kazuya Doi, Hiroshi Oue, Shiho Kajihara, Kazuhiko Hayashi, Yasumasa Akagawa.   

Abstract

The implant stability quotient (ISQ) has been widely evaluated in clinical studies and animal experiments. However, accurate measurement is often difficult in animal models. In such cases, measurement of ISQ in bone is needed after formalin fixation. However, it is not yet clear how such fixation influences the measurement. The purpose of this study was to investigate the influence of formalin fixation on ISQ and the mechanical characteristics of bone. Fourteen tibias were harvested from rabbits; the samples from the left (length 60mm, control group) were soaked in saline and the samples from the right (length 60mm, fixation group) were fixed in 10% neutral-buffered formalin at 4°C for 4h. Three-point bending tests were done at 5mm/min to measure the maximum load and total absorbed energy. Twelve titanium implants (Brånemark System(®) Mk-III TiUnite, Nobel Biocare, Sweden) were placed into the edentulous molar site of the mandibles of 2 dogs and the ISQ was measured by Osstell(®) (control group) 3 months later. The implants involved in the bone block were then fixed for 4h (fixation group) and the ISQ measured. The maximum load values did not differ significantly between the control and fixation groups. Total absorbed energy was significantly higher in the control group than in the fixation group. ISQ did not differ significantly between the groups. These results suggest that formalin fixation of bone might affect some of the mechanical characteristics of bone, but not its ISQ.
Copyright © 2012 The British Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  Bone; Bone mechanical characteristics; Formalin; Implant stability quotient (ISQ)

Mesh:

Substances:

Year:  2012        PMID: 23036835     DOI: 10.1016/j.bjoms.2012.08.009

Source DB:  PubMed          Journal:  Br J Oral Maxillofac Surg        ISSN: 0266-4356            Impact factor:   1.651


  5 in total

1.  Does formalin fixation influence MSCT/CBCT accuracy?

Authors:  Anna Seidel; Bastian Bergauer; Michael Lell; Thomas Buder; Cornelius von Wilmowsky; Eva Dach; Manfred Wichmann; Ragai-Edward Matta
Journal:  Surg Radiol Anat       Date:  2017-08-21       Impact factor: 1.246

2.  Influence of implant surface topography on primary stability in a standardized osteoporosis rabbit model study.

Authors:  Hiroshi Oue; Kazuya Doi; Yoshifumi Oki; Yusuke Makihara; Takayasu Kubo; Vittoria Perrotti; Adriano Piattelli; Yasumasa Akagawa; Kazuhiro Tsuga
Journal:  J Funct Biomater       Date:  2015-03-18

3.  Effect of two (short-term) storage methods on load to failure testing of murine bone tissue.

Authors:  Thomas M Tiefenboeck; Stephan Payr; Olga Bajenov; Thomas Koch; Micha Komjati; Kambiz Sarahrudi
Journal:  Sci Rep       Date:  2019-04-11       Impact factor: 4.379

4.  Novel fabrication of porous titanium by a resin-impregnated titanium substitution technique for bone reconstruction.

Authors:  Reiko Kobatake; Kazuya Doi; Takayasu Kubo; Yusuke Makihara; Yoshifumi Oki; Miyuki Yokoi; Hanako Umehara; Kazuhiro Tsuga
Journal:  RSC Adv       Date:  2019-01-04       Impact factor: 4.036

5.  An ex vivo model in human femoral heads for histopathological study and resonance frequency analysis of dental implant primary stability.

Authors:  Pedro Hernández-Cortés; Alberto Monje; Pablo Galindo-Moreno; Andrés Catena; Inmaculada Ortega-Oller; José Salas-Pérez; Francisco Mesa; Rafael Gómez-Sánchez; Mariano Aguilar; David Aguilar; Francisco O'Valle
Journal:  Biomed Res Int       Date:  2014-06-04       Impact factor: 3.411

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.