Right ventricular pressure during ventricular arrhythmias in humans: potential implications for implantable antitachycardia devices.

A D Sharma1, T D Bennett, M Erickson, G J Klein, R Yee, G Guiraudon.   

Abstract

Implantable defibrillators use algorithms based on ventricular electrographic data to detect the onset and termination of arrhythmias, but these algorithms do not always differentiate hemodynamically stable from unstable arrhythmias. Although, ideally, left ventricular function should be used to assess the hemodynamic state, right ventricular pulse pressure can be assessed in humans on a long-term basis with a transvenous lead. The potential utility of right ventricular pulse pressure to assess hemodynamic stability was studied in 22 patients with induced ventricular arrhythmias. Right ventricular pressure was measured with use of a transvenous right ventricular endocardial pacing lead with a piezoelectric bender pressure sensor 3 cm from its tip. Single ventricular premature paced beats administered in up to a bigeminal frequency did not alter the mean right ventricular pulse pressure (control 33.7 +/- 26, bigeminy 35.7 +/- 26 mm Hg). Twenty-one episodes of induced ventricular tachycardia were studied in the electrophysiology laboratory. Five seconds after tachycardia induction, hemodynamically stable ventricular tachycardia had a longer cycle length (294 +/- 41 ms) and the right ventricular pulse pressure ratio was higher (0.55 +/- 0.26) than that in unstable ventricular tachycardia (cycle length 256 +/- 55 ms, p = 0.06; pulse pressure ratio 0.26 +/- 0.09, p less than 0.05). Twenty episodes of ventricular fibrillation were induced in eight patients. One second after induction, right ventricular pulse pressure decreased from 25 +/- 5 to 6 +/- 3 mm Hg (p less than 0.05). On the first beat after defibrillation, right ventricular pulse pressure increased to 24 +/- 14 mm Hg, a level not significantly different from that before the induction of ventricular fibrillation.(ABSTRACT TRUNCATED AT 250 WORDS)

Entities:  

Mesh:

Year:  1990        PMID: 2303634     DOI: 10.1016/0735-1097(90)90640-b

Source DB:  PubMed          Journal:  J Am Coll Cardiol        ISSN: 0735-1097            Impact factor:   24.094


  2 in total

Review 1.  Current approaches and future developments in automatic tachycardia detection and diagnosis.

Authors:  P S Astridge; G C Kaye; E J Perrins
Journal:  Br Heart J       Date:  1993-08

2.  Effects of mechano-electric feedback on scroll wave stability in human ventricular fibrillation.

Authors:  Yuxuan Hu; Viatcheslav Gurev; Jason Constantino; Jason D Bayer; Natalia A Trayanova
Journal:  PLoS One       Date:  2013-04-03       Impact factor: 3.240

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.