Literature DB >> 23034796

64-slice coronary computed tomography angiography using low tube voltage of 80 kV in subjects with normal body mass indices: comparative study using 120 kV.

Bo Ram Jun1, Hwan Seok Yong, Eun-Young Kang, Ok Hee Woo, Eun Jung Choi.   

Abstract

BACKGROUND: The radiation dose of coronary computed tomography (CT) angiography (CCTA) is generally higher than that of CT scans of other parts of the body, and there is concern that the high radiation dose may result in increased cancer risk. Although various techniques have recently been introduced to lower the radiation dose of CCTA, there has been no direct comparison between protocols with 80 and 120 kV.
PURPOSE: To assess the image quality and radiation dose of 80-kV electrocardiography (ECG)-gated CCTA in subjects with a normal body mass index (BMI), compared to 120-kV ECG-gated CCTA.
MATERIAL AND METHODS: This retrospective study was approved by our local ethics board, and the requirement of written informed consent was waived. We analyzed the CCTA images of 100 subjects with BMIs <25 kg/m(2). Fifty subjects underwent 120-kV CCTA, and the other 50 subjects underwent 80-kV CCTA. Two blinded observers independently evaluated the subjective image quality of the coronary arteries. The objective image quality (signal-to-noise ratio [SNR] and contrast-to-noise ratio [CNR]) and radiation dose were also measured in each group.
RESULTS: Although the objective image quality of the 80-kV protocol images was significantly poorer than that of 120-kV protocol images (mean SNR, 14.9 ± 4.7 vs. 19.8 ± 4.4, P < 0.0001; mean CNR, 15.2 ± 4.8 vs. 21.6 ± 4.7, P < 0.0001), there was no significant difference in the subjective image quality between the two groups (mean image score, 4.7 ± 1.1 vs. 4.5 ± 0.7 for radiologist 1, P = 0.273; 5.0 ± 1.0 vs. 4.8 ± 1.0 for radiologist 2, P = 0.197). The radiation dose was reduced by 70% with the 80-kV protocol and by 88% with the 80-kV and ECG-based tube current modulation than with the 120-kV protocol (3.42 ± 1.16 and 2.9 ± 0.8 vs. 11.49 ± 3.62 mSv, P < 0.0001).
CONCLUSION: The low tube voltage CCTA protocol using 80 kV allows significant reduction of the radiation dose without impairing the subjective image quality in subjects with normal BMIs.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 23034796     DOI: 10.1258/ar.2012.110573

Source DB:  PubMed          Journal:  Acta Radiol        ISSN: 0284-1851            Impact factor:   1.990


  10 in total

1.  Adenosine-stress dynamic myocardial perfusion imaging using 128-slice dual-source CT in patients with normal body mass indices: effect of tube voltage, tube current, and iodine concentration on image quality and radiation dose.

Authors:  Sung Mok Kim; Young Kwon Cho; Yeon Hyeon Choe
Journal:  Int J Cardiovasc Imaging       Date:  2014-08-26       Impact factor: 2.357

2.  Diagnostic accuracy of low and high tube voltage coronary CT angiography using an X-ray tube potential-tailored contrast medium injection protocol.

Authors:  Moritz H Albrecht; John W Nance; U Joseph Schoepf; Brian E Jacobs; Richard R Bayer; Sheldon E Litwin; Michael A Reynolds; Katharina Otani; Stefanie Mangold; Akos Varga-Szemes; Domenico De Santis; Marwen Eid; Georg Apfaltrer; Christian Tesche; Markus Goeller; Thomas J Vogl; Carlo N De Cecco
Journal:  Eur Radiol       Date:  2017-11-27       Impact factor: 5.315

3.  Comparison of diagnostic performance between single- and multiphasic contrast-enhanced abdominopelvic computed tomography in patients admitted to the emergency department with abdominal pain: potential radiation dose reduction.

Authors:  Shin Hye Hwang; Je Sung You; Mi Kyong Song; Jin-Young Choi; Myeong-Jin Kim; Yong Eun Chung
Journal:  Eur Radiol       Date:  2014-11-26       Impact factor: 5.315

Review 4.  Subject-specific analysis of joint contact mechanics: application to the study of osteoarthritis and surgical planning.

Authors:  Corinne R Henak; Andrew E Anderson; Jeffrey A Weiss
Journal:  J Biomech Eng       Date:  2013-02       Impact factor: 2.097

5.  Feasibility of prospectively ECG-triggered high-pitch coronary CT angiography with 30 mL iodinated contrast agent at 70 kVp: initial experience.

Authors:  Long Jiang Zhang; Li Qi; Jing Wang; Chun Xiang Tang; Chang Sheng Zhou; Xue Man Ji; James V Spearman; Carlo Nicola De Cecco; Felix G Meinel; U Joseph Schoepf; Guang Ming Lu
Journal:  Eur Radiol       Date:  2014-04-16       Impact factor: 5.315

6.  Low radiation dose computed tomography coronary angiography: evaluation of the variations in coronary arteries.

Authors:  Nurullah Dogan; Aydin Dursun; Hakan Ozkan; Serdar Karataş; Nuran Celiloglu; Fahriye Vatansever Agca
Journal:  Surg Radiol Anat       Date:  2016-05-18       Impact factor: 1.246

7.  Image quality and radiation dose of low tube voltage 3rd generation dual-source coronary CT angiography in obese patients: a phantom study.

Authors:  Felix G Meinel; Christian Canstein; U Joseph Schoepf; Martin Sedlmaier; Bernhard Schmidt; Brett S Harris; Thomas G Flohr; Carlo N De Cecco
Journal:  Eur Radiol       Date:  2014-05-10       Impact factor: 5.315

8.  High-pitch coronary CT angiography at 70 kVp with low contrast medium volume: comparison of 80 and 100 kVp high-pitch protocols.

Authors:  Long Jiang Zhang; Li Qi; Carlo N De Cecco; Chang Sheng Zhou; James V Spearman; U Joseph Schoepf; Guang Ming Lu
Journal:  Medicine (Baltimore)       Date:  2014-11       Impact factor: 1.889

9.  Cardiac helical CT involving a low-radiation-dose protocol with a 100-kVp setting: Usefulness of hybrid iterative reconstruction and display preset optimization.

Authors:  Yuji Iyama; Takeshi Nakaura; Koichi Yokoyama; Masafumi Kidoh; Yasuyuki Yamashita
Journal:  Medicine (Baltimore)       Date:  2016-11       Impact factor: 1.889

10.  Comparison of Image Quality, Diagnostic Accuracy and Radiation Dose Between Flash Model and Retrospective ECG-Triggered Protocols in Dual Source Computed Tomography (DSCT) in Congenital Heart Diseases.

Authors:  Rong Wang; Xiang-Jiu Xu; Gang Huang; Xing Zhou; Wen-Wen Zhang; Ya-Qiong Ma; Xiao-Na Zuo
Journal:  Pol J Radiol       Date:  2017-02-28
  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.