BACKGROUND: Colon capsule endoscopy (CCE) is a noninvasive technique for the detection of colorectal lesions. However, for CCE to be offered as an out-of-clinic procedure, the system needs to automatically alert the patient when to ingest the laxative (booster).
OBJECTIVE: We tested the reliability of the automatic detection of the small-bowel (SB) mucosa and the subsequent alert for booster ingestion by the Data Recorder 3 (DR3) of the second-generation CCE (CCE-2). DESIGN AND
SETTING: Retrospective analysis. PATIENTS AND INTERVENTION: Data from 120 consecutive cases of CCE-2 were analyzed for proper DR3 automatic detection of the capsule entering the SB to prompt the patient to ingest the laxative booster. MAIN OUTCOME MEASUREMENTS: Accuracy of the DR3 for detecting the SB mucosa.
RESULTS: The DR3 correctly identified the proper time for ingestion of the laxative (booster) in 118 of 120 cases, corresponding to a sensitivity of 98.3% (95% CI, 97%-100%). The median time difference between DR3 automatic SB detection to the observed entrance of the capsule into the SB was 3 minutes 30 seconds (interquartile range 2 minutes 35 seconds to 5 minutes 57 seconds). LIMITATION: Retrospective analysis.
CONCLUSIONS: The 98.3% sensitivity of the DR3 for automatic identification of the SB mucosa and subsequent alert for the first laxative (booster) ingestion paves the way for CCE-2 to be offered as an out-of-clinic procedure.
Copyright © 2012 American Society for Gastrointestinal Endoscopy. Published by Mosby, Inc. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 23025975     DOI: 10.1016/j.gie.2012.07.034

Source DB:  PubMed          Journal:  Gastrointest Endosc        ISSN: 0016-5107            Impact factor:   9.427


  8 in total

Review 1.  Colon capsule endoscopy: current status and future directions.

Authors:  Andrea O Tal; Johannes Vermehren; Jörg G Albert
Journal:  World J Gastroenterol       Date:  2014-11-28       Impact factor: 5.742

Review 2.  Video capsule endoscopy: perspectives of a revolutionary technique.

Authors:  Simon Bouchard; Mostafa Ibrahim; Andre Van Gossum
Journal:  World J Gastroenterol       Date:  2014-12-14       Impact factor: 5.742

Review 3.  PillCam colon capsule endoscopy (PCCE) in colonic diseases.

Authors:  Dan Carter; Rami Eliakim
Journal:  Ann Transl Med       Date:  2016-08

4.  Second-generation colon capsule endoscopy is feasible in the out-of-clinic setting.

Authors:  Samuel Nathan Adler; Cesare Hassan; Yoav Metzger; Yishai Sompolinsky; Cristiano Spada
Journal:  Surg Endosc       Date:  2013-09-17       Impact factor: 4.584

5.  PillCamColon2 after incomplete colonoscopy - A prospective multicenter study.

Authors:  Peter Baltes; Marc Bota; Jörg Albert; Michael Philipper; Hans-Georg Hörster; Friedrich Hagenmüller; Ingo Steinbrück; Ralf Jakobs; Matthias Bechtler; Dirk Hartmann; Horst Neuhaus; Jean-Pierre Charton; Rupert Mayershofer; Horst Hohn; Thomas Rösch; Stefan Groth; Tanja Nowak; Peter Wohlmuth; Martin Keuchel
Journal:  World J Gastroenterol       Date:  2018-08-21       Impact factor: 5.742

6.  Novel imaging enhancements in capsule endoscopy.

Authors:  Mostafa Ibrahim; Andre Van Gossum
Journal:  Gastroenterol Res Pract       Date:  2013-06-26       Impact factor: 2.260

Review 7.  Colon Capsule Endoscopy: Where Are We and Where Are We Going.

Authors:  Yoo Min Han; Jong Pil Im
Journal:  Clin Endosc       Date:  2016-09-22

8.  Initial US evaluation of second-generation capsule colonoscopy for detecting colon polyps.

Authors:  Douglas R Morgan; Pramod R Malik; David P Romeo; Douglas K Rex
Journal:  BMJ Open Gastroenterol       Date:  2016-05-03
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.