Literature DB >> 23025174

A linear-actuated torsional device to replicate clinically relevant spiral fractures in long bones.

W Brent Edwards1, Karen L Troy.   

Abstract

To better understand the mechanisms underlying spiral fracture we would like to carry out biomechanical tests of long bones loaded in torsion to failure. A device was fabricated to perform torsional tests of long bones using a single-axis linear actuator. The principal operation of the device was to transform the vertical displacement of a material testing machine's linear actuator into rotational movement using a spur gear and rack system. Accuracy and precision of the device were quantified using cast-acrylic rods with known torque-rotation behavior. Cadaveric experimentation was used to replicate a clinically relevant spiral fracture in eleven human proximal tibiae; strain-gage data were recorded for a single specimen. The device had an experimental error of less than 0.2 Nm and was repeatable to within 0.3%. Strain gage data were in line with those expected from pure torsion and the cadaveric tibiae illustrated spiral fractures at ultimate torque and rotation values of 130.6 +/- 53.2 Nm and 8.3 +/- 1.5 degrees, respectively. Ultimate torque was highly correlated with DXA assessed bone mineral density (r = 0.87; p < 0.00 1). The device presented is applicable to any torsional testing of long bone when only a single-axis linear actuator is available.

Entities:  

Mesh:

Year:  2012        PMID: 23025174      PMCID: PMC3464952          DOI: 10.1177/0954411912452996

Source DB:  PubMed          Journal:  Proc Inst Mech Eng H        ISSN: 0954-4119            Impact factor:   1.617


  9 in total

1.  Extremity fractures of patients with spinal cord injuries.

Authors:  A E COMARR; R H HUTCHINSON; E BORS
Journal:  Am J Surg       Date:  1962-06       Impact factor: 2.565

2.  Relationship between the duration of paralysis and bone structure: a pQCT study of spinal cord injured individuals.

Authors:  P Eser; A Frotzler; Y Zehnder; L Wick; H Knecht; J Denoth; H Schiessl
Journal:  Bone       Date:  2004-05       Impact factor: 4.398

3.  Longitudinal study of bone mineral content in the lumbar spine, the forearm and the lower extremities after spinal cord injury.

Authors:  F Biering-Sørensen; H H Bohr; O P Schaadt
Journal:  Eur J Clin Invest       Date:  1990-06       Impact factor: 4.686

4.  The biomechanics of torsional fractures: the effect of loading on ultimate properties.

Authors:  G J Sammarco; A H Burstein; W L Davis; V H Frankel
Journal:  J Biomech       Date:  1971-03       Impact factor: 2.712

5.  Lower extremity fractures in patients with spinal cord injury.

Authors:  A A Freehafer; C M Hazel; C L Becker
Journal:  Paraplegia       Date:  1981

6.  The mechanical characteristics of the long bones of the lower extremity in torsional loading.

Authors:  M Martens; R van Audekercke; P de Meester; J C Mulier
Journal:  J Biomech       Date:  1980       Impact factor: 2.712

7.  Spiral fracture of cortical bone.

Authors:  W Bonfield; M D Grynpas
Journal:  J Biomech       Date:  1982       Impact factor: 2.712

8.  Osteoporotic fractures and hospitalization risk in chronic spinal cord injury.

Authors:  L R Morse; R A Battaglino; K L Stolzmann; L D Hallett; A Waddimba; D Gagnon; A A Lazzari; E Garshick
Journal:  Osteoporos Int       Date:  2008-06-26       Impact factor: 4.507

9.  Fracture rates and risk factors for fractures in patients with spinal cord injury.

Authors:  P Vestergaard; K Krogh; L Rejnmark; L Mosekilde
Journal:  Spinal Cord       Date:  1998-11       Impact factor: 2.772

  9 in total
  2 in total

1.  Torsional stiffness and strength of the proximal tibia are better predicted by finite element models than DXA or QCT.

Authors:  W Brent Edwards; Thomas J Schnitzer; Karen L Troy
Journal:  J Biomech       Date:  2013-05-13       Impact factor: 2.712

2.  Using mechanical testing to assess texturing of prosthetic sockets to improve suspension in the transverse plane and reduce rotation.

Authors:  Julia Quinlan; Vasanth Subramanian; Jessica Yohay; Brad Poziembo; Stefania Fatone
Journal:  PLoS One       Date:  2020-06-11       Impact factor: 3.240

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.