Vitamin B(12) Immunoassay on Roche Elecsys 2010: Effects of High Excess Concentration of Serum Vitamin B(12) in CKD Patients on Parenteral Administration.

Surupa Basu1, Subimal Chaudhuri.   

Abstract

Vitamin B(12) being water soluble is excreted in the urine when administered in excess. The probability of finding an abnormally excess serum concentration would be almost surreal. We report a peculiar clinical situation that may impact the vitamin B(12) immunoassay on the Roche Elecsys 2010 due to excess analyte concentration. In separate episodes (Feb and June 2010), the Biochemistry laboratory of a tertiary-care hospital, Kolkata, India, encountered two critically ill patients with background chronic kidney disease (CKD), low urine output, and on cyanocoabalamin supplementation, who had serum vitamin B(12) concentrations far exceeding expected values; even post dialysis. The B(12) assays (pmol/l) were performed using electrochemiluminiscence immunoassay on Roche Elecsys 2010, the assay validity confirmed by concomitant quality control runs. The immunoassays failed to deliver results, flagged with "signal level below limit". Biotin therapy was ruled out as a possible interferent. In the first episode, re-assay of a repeat draw yielded same outcome; outsourcing on Immulite provided concentration of >738 pmol/l. Serial dilution gave result of >29520 pmol/l on Elecsys 2010. In the second, we gained from past experience. Vitamin B(12) concentration >59040 pmol/l was conveyed to the treating nephrologist the very day. The B(12) immunoassay on the Elecsys 2010 employs sequential incubation steps for competitive binding that is compromised in the event of abnormally excess B(12) concentration in patient sera akin to the prozone effect. This knowledge may be beneficial while assaying sera of CKD patients to avoid financial loss due unnecessary repeats and delay in turnaround time.

Entities:  

Keywords:  Dialysis; Hook effect; Interference; Renal failure; Roche Elecsys 2010; Vitamin B12 immunoassay

Year:  2011        PMID: 23024480      PMCID: PMC3210246          DOI: 10.1007/s12291-011-0129-z

Source DB:  PubMed          Journal:  Indian J Clin Biochem        ISSN: 0970-1915


  3 in total

1.  Hook effect in immunometric assays for prostate-specific antigen.

Authors:  A Charrié; G Charriére; A Guerrier
Journal:  Clin Chem       Date:  1995-03       Impact factor: 8.327

2.  Measurement of serum ferritin by a 2-site immunoradiometric assay.

Authors:  L E Miles; D A Lipschitz; C P Bieber; J D Cook
Journal:  Anal Biochem       Date:  1974-09       Impact factor: 3.365

3.  Concentrations of vitamin C, vitamin B12 and folic acid in patients treated with hemodialysis and on-line hemodiafiltration or hemofiltration.

Authors:  Ingela Fehrman-Ekholm; Agneta Lotsander; Katarina Logan; David Dunge; Ingegerd Odar-Cederlöf; Anders Kallner
Journal:  Scand J Urol Nephrol       Date:  2008
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.