Literature DB >> 23024054

Immediate results of bifurcational stenting assessed with optical coherence tomography.

Nicola Viceconte1, Pawel Tyczynski, Giuseppe Ferrante, Nicolas Foin, Pak Hei Chan, Eduardo Alegrìa Barrero, Carlo Di Mario.   

Abstract

BACKGROUND: A tubular stent may adapt with difficulty to coronary bifurcation lesions (CBLs).
METHODS: Time domain or frequency domain (FD) optical coherence tomography (OCT) was performed to assess strut apposition immediately after stent implantation across four segments inside the bifurcation, in a consecutive series of patients. OCT pullbacks were performed in the main vessel (MV).
RESULTS: A total of 13,142 struts in 45 CBL in 41 patients were assessed. Strut malapposition was significantly more frequent in the half bifurcation facing the side-branch (SB) ostium (42.9%) than in the proximal segment of the bifurcation 11.8%, half bifurcation opposite the SB 6.7%, or the distal segment 5.7% (all P < 0.0001). Lesions (n = 15) treated with stenting of both MV and SB had a total higher rate of malapposition than those (n = 30) treated with stenting of the MV only (17.6% vs. 9.5%; P = 0.0014). In latter group, lesions treated with FD-OCT-guided stent implantation (n = 13) presented a lower rate of malapposition than those treated with conventional angiographic-guided stent implantation (n = 17) (7.1% vs. 17.5%; P = 0.005).
CONCLUSIONS: In CBL, strut malapposition is particularly high at the SB ostium. However, a strategy of stenting MV only with adjunctive FD-OCT guidance is associated with lower rates of malapposition.
Copyright © 2012 Wiley Periodicals, Inc.

Entities:  

Mesh:

Year:  2012        PMID: 23024054     DOI: 10.1002/ccd.24337

Source DB:  PubMed          Journal:  Catheter Cardiovasc Interv        ISSN: 1522-1946            Impact factor:   2.692


  5 in total

1.  Differences of side branch jailing between left main-left anterior descending artery stenting and left main-left circumflex artery stenting with Nobori biolimus-eluting stent.

Authors:  Fumiaki Nakao; Takayuki Okamura; Takeshi Suetomi; Jutaro Yamada; Takeshi Nakamura; Tooru Ueda; Takamasa Oda; Masashi Kanemoto; Yasuhiro Ikeda; Takashi Fujii; Masafumi Yano
Journal:  Heart Vessels       Date:  2016-02-15       Impact factor: 2.037

2.  Quantitative analysis of the side-branch orifice after bifurcation stenting using en-face processing of OCT images: a comparison between Xience V and Resolute Integrity stents.

Authors:  Yoshiyasu Minami; Zhao Wang; Aaron D Aguirre; Stephen Lee; Shiro Uemura; Tsunenari Soeda; Rocco Vergallo; Owen C Raffel; Peter Barlis; Tomonori Itoh; Hang Lee; James Fujimoto; Ik-Kyung Jang
Journal:  Coron Artery Dis       Date:  2016-01       Impact factor: 1.439

Review 3.  Optical coherence tomography: from research to practice.

Authors:  Juan Luis Gutiérrez-Chico; Eduardo Alegría-Barrero; Rodrigo Teijeiro-Mestre; Pak Hei Chan; Hiroto Tsujioka; Ranil de Silva; Nicola Viceconte; Alistair Lindsay; Tiffany Patterson; Nicolas Foin; Takashi Akasaka; Carlo di Mario
Journal:  Eur Heart J Cardiovasc Imaging       Date:  2012-02-13       Impact factor: 6.875

4.  Three-dimensional reconstruction of optical coherence tomography for improving bifurcation stenting.

Authors:  Takayuki Okamura; Tatsuhiro Fujimura; Masafumi Yano
Journal:  J Cardiol Cases       Date:  2016-03-14

Review 5.  Should kissing balloon inflation after main vessel stenting be routine in the one-stent approach? A systematic review and meta-analysis of randomized trials.

Authors:  Ming Zhong; Biao Tang; Qiang Zhao; Jian Cheng; Qiangsong Jin; Shenwen Fu
Journal:  PLoS One       Date:  2018-06-27       Impact factor: 3.240

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.