Feasibility of 3D ultrasound to evaluate upper extremity nerves.

M-T Girtler1, A Krasinski, C Dejaco, H H Kitzler, L G Cui, S Sherebrin, L Gardi, R K Chhem, A Fenster, C Romagnoli, T De Zordo.   

Abstract

PURPOSE: This study investigates the performance of a 3 D Ultrasound (US) system in imaging elbow and wrist nerves.
MATERIALS AND METHODS: Twenty healthy volunteers with asymptomatic median, ulnar and radial nerves were prospectively investigated. Bilateral 3DUS scans of the elbows and wrists were acquired by using a commercially available US scanner (18 MHz, AplioXG, Toshiba) and stored as a 3 D volume by a dedicated software (CURE, Robarts Research Institute). Retrospectively, qualitative (image quality, atypical nerve location, findings potentially associated with compression neuropathy) and quantitative (cross-sectional area measurements) evaluations were performed.
RESULTS: In all 200 nerves 3DUS was feasible (100%). Image quality was insufficient in 13.5% (25 ulnar nerve elbow, 2 radial nerve) and sonomorphology was not assessable in those nerves. Measurement of cross sectional areas was feasible in all nerves (100%). Median cross-sectional area (range) were: median nerve elbow 7 mm2 (6-9), radial nerve 3 mm2 (1-4), ulnar nerve elbow 8 mm2 (5-11), median nerve wrist 8 mm2 (5-10), and ulnar nerve wrist 4 mm2 (2-6). No significant changes in nerve cross-sectional area along each nerve was found. Ulnar nerve subluxation was found in 2 nerves (6.7%). No anconeus epitrochlearis muscle or osteophytes were found.
CONCLUSION: 3DUS is a feasible method for assessing nerves of the upper extremity and has been shown to provide a good overview of the median, ulnar and radial nerve at the elbow and wrist, but is limited for evaluation of the ulnar nerve in the cubital tunnel. This technique enables reliable measurements at different locations along the nerve. © Georg Thieme Verlag KG Stuttgart · New York.

Entities:  

Mesh:

Year:  2012        PMID: 23023451     DOI: 10.1055/s-0032-1325397

Source DB:  PubMed          Journal:  Ultraschall Med        ISSN: 0172-4614            Impact factor:   6.548


  2 in total

1.  Correlation between Ultrasonography Findings and Electrodiagnostic Severity in Carpal Tunnel Syndrome: 3D Ultrasonography.

Authors:  Hee Kyu Kwon; Hyo Jung Kang; Chan Woo Byun; Joon Shik Yoon; Chang Ho Kang; Sung Bum Pyun
Journal:  J Clin Neurol       Date:  2014-10-06       Impact factor: 3.077

2.  Investigation of the Diagnostic Value of Ultrasonography for Radial Neuropathy Located at the Spiral Groove.

Authors:  Seojin Song; Yeonji Yoo; Sun Jae Won; Hye Jung Park; Won Ihl Rhee
Journal:  Ann Rehabil Med       Date:  2018-08-31
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.