Design of ridge filters for spread-out Bragg peaks with Monte Carlo simulation in carbon ion therapy.

M Sakama1, T Kanai, Y Kase, K Yusa, M Tashiro, K Torikai, H Shimada, S Yamada, T Ohno, T Nakano.   

Abstract

Spread-out Bragg peaks made by ridge filters or wheel range modulators are used in charged particle therapy with passive methods to achieve uniform biological responses in irradiated tumors. Following the biological responses needed to design the ridge filters, which were developed at the National Institute of Radiological Sciences in Japan, new ridge filters were designed using recent developments in heavy-ion reactions and dosimetry. The Monte Carlo code of Geant4 was used to calculate the qualities of carbon ion beams in a water phantom. The results obtained from the simulation were corrected so that they agreed with the measurements of depth dose distributions. The calculations of biological responses to fragments other than carbon ions were assumed to be for helium ions. The measured dose distributions with the designed ridge filters were compared to the calculated distributions. A beam modifying system using this adaptable method was successively applied to carbon ion therapy at Gunma University.

Entities:  

Mesh:

Year:  2012        PMID: 23022653     DOI: 10.1088/0031-9155/57/20/6615

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  6 in total

1.  Physical and biological beam modeling for carbon beam scanning at Osaka Heavy Ion Therapy Center.

Authors:  Shinichiro Fujitaka; Yusuke Fujii; Hideaki Nihongi; Satoshi Nakayama; Masaaki Takashina; Noriaki Hamatani; Toshiro Tsubouchi; Masashi Yagi; Kazumasa Minami; Kazuhiko Ogawa; Junetsu Mizoe; Tatsuaki Kanai
Journal:  J Appl Clin Med Phys       Date:  2021-05-16       Impact factor: 2.102

2.  Estimation of linear energy transfer distribution for broad-beam carbon-ion radiotherapy at the National Institute of Radiological Sciences, Japan.

Authors:  Nobuyuki Kanematsu; Naruhiro Matsufuji; Taku Inaniwa
Journal:  Radiol Phys Technol       Date:  2018-02-22

3.  Design of spread-out Bragg peaks in hadron therapy with oxygen ions.

Authors:  Ladan Rezaee
Journal:  Rep Pract Oncol Radiother       Date:  2018-09-04

4.  Commissioning a newly developed treatment planning system, VQA Plan, for fast-raster scanning of carbon-ion beams.

Authors:  Masashi Yagi; Toshiro Tsubouchi; Noriaki Hamatani; Masaaki Takashina; Hiroyasu Maruo; Shinichiro Fujitaka; Hideaki Nihongi; Kazuhiko Ogawa; Tatsuaki Kanai
Journal:  PLoS One       Date:  2022-05-10       Impact factor: 3.752

5.  Linear energy transfer-independent calibration of radiochromic film for carbon-ion beams.

Authors:  Mutsumi Tashiro; Motohiro Kawashima
Journal:  Phys Imaging Radiat Oncol       Date:  2022-08-08

6.  A Mathematical Method to Adjust MLC Leaf End Position for Accurate Dose Calculation in Carbon Ion Beam Radiation Therapy Treatment Planning System.

Authors:  Yan-Shan Zhang; Yan-Cheng Ye; Jia-Ming Wu
Journal:  Biomed Res Int       Date:  2021-10-21       Impact factor: 3.411

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.